The article describes the main achievements of the NUMEN project together with an updated and detailed overview of the related R&D activities and theoretical developments. NUMEN proposes an innovative technique to access the nuclear matrix elements entering the expression of the lifetime of the double beta decay by cross section measurements of heavy-ion induced Double Charge Exchange (DCE) reactions. Despite the two processes, namely neutrinoless double beta decay and DCE reactions, are triggered by the weak and strong interaction respectively, important analogies are suggested. The basic point is the coincidence of the initial and final state many-body wave-functions in the two types of processes and the formal similarity of the transition operators. First experimental results obtained at the INFN-LNS laboratory for the 40 Ca( 18 O, 18 Ne) 40 Ar reaction at 270 MeV, give encouraging indication on the capability of the proposed technique to access relevant quantitative information.The two major aspects for this project are the K800 Superconducting Cyclotron and MAGNEX spectrometer. The former is used for the acceleration of the required high resolution and low emittance heavy ion beams and the latter is the large acceptance magnetic spectrometer for the detection of the ejectiles. The use of the high-order trajectory reconstruction technique, implemented in MAGNEX, allows to reach the experimental resolution and sensitivity required for the accurate measurement of the DCE cross sections at forward angles. However, the tiny values of such cross sections and the resolution requirements demand beam intensities much larger than manageable with the present facility. The on-going upgrade of the INFN-LNS facilities in this perspective is part of the NUMEN project and will be discussed in the article.3
An upgraded and improved version of the focal plane detector (FPD) of the large-acceptance magnetic spectrometer MAGNEX is described here. The FPD consists of a tracker operating at low pressure and of a silicon detector wall. Thanks to a different geometry of the electron multiplication and induction elements, the new detector guarantees a superior signal to noise ratio, resulting in a more accurate tracking and a cleaner identification of the detected heavy ions. The new detector has been tested by using a 18 O beam at an energy of 84 MeV. A description of the new FPD that pinpoints the innovation and the obtained performances is given and discussed in details.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.