The good relationship between propofol and BIS demonstrated in children as in adults suggested a slightly lower sensitivity to propofol in children. As the predictability of plasma propofol concentrations with the classical pharmacokinetic/pharmacodynamic models is limited in children, a cerebral pharmacodynamic feedback, such as BIS, may be useful in this population.
Agitation observed during sevoflurane induction was not associated with seizures. Sevoflurane induction induced a marked inhibition of parasympathetic control of heart rate.
The present study was designed to compare induction and recovery characteristics of sevoflurane and halothane anesthesia in children, and to assess the hemodynamic profile of both anesthetics during induction and maintenance of anesthesia. Thirty-four children (aged 9 mo-9 yr) scheduled for ambulatory surgery were allocated randomly to groups to receive either halothane (HALO, n = 17) or sevoflurane (SEVO, n = 17) in a mixture of O2 and N2O (40:60) for mask induction and maintenance of anesthesia. The inspired concentrations used for inhalation via a mask were increased every five breaths and were successively 1%, 2%, 3%, and 3.5% for HALO and 2%, 4%, 6%, and 7% for SEVO. After tracheal intubation, expired concentration was maintained at 1 minimum alveolar anesthetic concentration (MAC) corrected for age until skin closure. Analgesia was provided by epidural anesthesia using a mixture of plain 1% lidocaine and 0.25% bupivacaine. Induction and recovery characteristics as well as hemodynamic data were recorded. The two groups were identical in age, weight, and duration of anesthesia and surgery. Time to intubation was the same between groups. In the SEVO group, five children exhibited mild excitement, while in the HALO group, one mild laryngospasm and one transient cardiovascular deterioration were observed. In the SEVO group, a significant increase in heart rate (HR) was observed before tracheal intubation, but during maintenance of anesthesia HR and systolic arterial pressure (SAP) did not change compared to control values. In the HALO group, HR did not change throughout the study, whereas SAP remained significantly below control values throughout both induction and maintenance of anesthesia.(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.