The targeted plasma parameters of the compact spherical tokamak (ST) Globus-M have basically been achieved. The reasons that prevent further extension of the operating space are discussed. The operational limits of Globus-M together with an understanding of the limiting reasons form the basis for defining the design requirements for the next-step, Globus-M2. The recent experimental and theoretical results achieved with Globus-M are discussed, the operational problems and the research programme are summarized and finally, the targeted Globus-M2 parameters are presented. The magnetic field and plasma current in Globus-M2 will be increased to 1 T and 0.5 MA, respectively. The plasma dimensions will remain unchanged. With auxiliary heating at a high average plasma density, the temperatures will be in the keV range and the collisionality parameter with ν * 1 will define the operational conditions. Noninductive current drive will be a major element of the programme. The engineering design issues of Globus-M2 tokamak are discussed and the technical tokamak parameters are confirmed by thermal load and stress analysis simulations. The experimental results obtained on Globus-M2 and the limits of its performance should clarify the feasibility of an ST-based super compact neutron source.
Progress in the theoretical and experimental development of the plasma jet source and injection of hydrogen plasma and neutral gas jets into the Globus-M spherical tokamak is discussed. An experimental test bed is described for investigation of intense plasma jets that are generated by a double-stage plasma gun consisting of an intense source for neutral gas production and a conventional pulsed coaxial accelerator. A procedure for optimizing the accelerator parameters so as to achieve the maximum possible flow velocity with a limited discharge current and a reasonable length of the coaxial electrodes is presented. The calculations are compared with experiment. Plasma jet parameters, among them pressure distribution across the jet, flow velocity, plasma density, etc, were measured. Plasma jets with densities of up to 10 22 m −3 , total numbers of accelerated particles (1-5)×10 19 , and flow velocities of 50-100 km s −1 were successfully injected into the plasma column of the Globus-M tokamak. Interferometric and Thomson scattering measurements confirmed deep jet penetration and a fast density rise (<0.5 ms) at all spatial points up to a radius r ≈ 0.3a. The plasma particle inventory increase by ∼50% (from 0.65 × 10 19 to 1 × 10 19 ) did not result in plasma degradation.
No abstract
Experiments and simulations to achieve high values of plasma parameters at the Globus-M spherical tokamak (ST) at moderate auxiliary heating power (0.2-0.8 MW) are described. Important distinguishing features are the low edge safety factor range, which is unusual for spherical tokamaks, 2.7 < q < 5 and small plasma-outer wall space (3-5 cm). High ion heating efficiency with NB injection was demonstrated. Results of numerical simulation of fast ion trajectories are described and fast ion generation during NB injection and ICR heating is discussed. Also results on their confinement and slowing down processes investigation are presented. Reasons for achievement of high IC heating efficiency are outlined. Reliable H-mode regime achievement is described. Transport ASTRA modeling demonstrated that during NB heated H-mode ion heat diffusivity remains neoclassical and the particle diffusion coefficient inside transport barrier decreases significantly. RGTi divertor tile analysis was performed after irradiation by plasma during big number of shots (10000 shots in average). Mixed layer composition is measured and deuterium retention in different tokamak first wall area is estimated. Plasma jet injection experiments with upgraded plasma jet are described. Jet penetration to the plasma center with immense increase of density and temperature drop is proved and analogy with pellet injection is outlined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.