Background: Antares is an algorithm for pulse wave analysis (PWA) by oscillometric blood pressure (BP) monitors in order to estimate central (aortic) blood pressure (cBP). Antares aims to enable brachial cuff-based BP monitors to be type II-devices, determining absolute cBP values independently of potential peripheral BP inaccuracies. The present study is an invasive validation of the Antares algorithm in the custo screen 400. Methods: We followed entirely the 2017 ARTERY protocol for validation of non-invasive cBP devices, the 2013 American National Standards Institute, Inc./Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2 and 2018 AAMI/European Society of Hypertension (ESH)/ISO validation standard protocols. In total, 191 patients undergoing cardiac catheterization were included, of which 145 patients entered analysis. Invasive cBP recordings were compared to simultaneous non-invasive cBP estimations using the Antares algorithm, integrated into an oscillometric BP monitor. Results: Mean difference between invasive and non-invasively estimated systolic cBP was 0.71 mmHg with standard deviation of 5.95 mmHg, fulfilling highest validation criteria. Conclusion: Antares is the first algorithm for estimation of cBP that entirely fulfills the 2017 ARTERY and AAMI/ESH/ISO validation protocols. The Antares algorithm turns the custo screen 400 BP monitor into a type II-device. Integration of Antares into commercially available BP monitors could make it possible to measure PWA parameters in virtually every practice in future.
Heart failure with preserved ejection fraction (HFpEF) is highly prevalent in patients on maintenance haemodialysis (HD) and lacks effective treatment. We investigated the effect of spironolactone on cardiac structure and function with a specific focus on diastolic function parameters. The MiREnDa trial examined the effect of 50 mg spironolactone once daily versus placebo on left ventricular mass index (LVMi) among 97 HD patients during 40 weeks of treatment. In this echocardiographic substudy, diastolic function was assessed using predefined structural and functional parameters including E/e’. Changes in the frequency of HFpEF were analysed using the comprehensive ‘HFA-PEFF score’. Complete echocardiographic assessment was available in 65 individuals (59.5 ± 13.0 years, 21.5% female) with preserved left ventricular ejection fraction (LVEF > 50%). At baseline, mean E/e’ was 15.2 ± 7.8 and 37 (56.9%) patients fulfilled the criteria of HFpEF according to the HFA-PEFF score. There was no significant difference in mean change of E/e’ between the spironolactone group and the placebo group (+ 0.93 ± 5.39 vs. + 1.52 ± 5.94, p = 0.68) or in mean change of left atrial volume index (LAVi) (1.9 ± 12.3 ml/m2 vs. 1.7 ± 14.1 ml/m2, p = 0.89). Furthermore, spironolactone had no significant effect on mean change in LVMi (+ 0.8 ± 14.2 g/m2 vs. + 2.7 ± 15.9 g/m2; p = 0.72) or NT-proBNP (p = 0.96). Treatment with spironolactone did not alter HFA-PEFF score class compared with placebo (p = 0.63). Treatment with 50 mg of spironolactone for 40 weeks had no significant effect on diastolic function parameters in HD patients.The trial has been registered at clinicaltrials.gov (NCT01691053; first posted Sep. 24, 2012).
Assessment of the left ventricular ejection fraction plays a key role in the echocardiographic diagnosis of heart failure. The parameter most commonly used is the ejection fraction computed with the biplane disc summation method of Simpson; however, there are numerous limitations to this method, such as the assumption of geometrical symmetry, a substantial intraobserver and interobserver variability, foreshortening of the left ventricle and insufficient image quality for endocardial tracking. Alternative parameters for the evaluation of left ventricular function should be taken into consideration. Speckle tracking echocardiography has proven to be a reliable prognostic factor and a good tool for differentiating cardiomyopathies. Simple measurements, which are also feasible with poor image quality, are mitral annular plane systolic excursion (MAPSE) and the velocity of mitral annular movement (Sm or S'). In mitral regurgitation, left ventricular dP/dt represents the time to build up a certain pressure gradient and is therefore a measure of the contractile force exerted. Three-dimensional echocardiography has proven to be an important tool not only for three-dimensional measurement of the left ventricular ejection fraction but also for multivectoral speckle tracking analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.