The concept of fire safety covers an extremely vast scope of issues. To ensure an adequate fire safety level, it is necessary to combine research and actions in several fields, such as the mathematical, physical, or numerical modelling of a fire phenomenon. Another problem is to design different types of fire protection, including alarm systems, sprinkler systems, and also roads and evacuation systems, in a manner that ensures maximum safety for the building’s users. A vital issue is the analysis of the static-strength response of the structure under fire conditions. This study, concerned with such analyses, is limited to steel truss structures. In technical approvals, manufacturers of fire-proofing materials do not account for the character of the performance of individual structural members. The components in compression need thicker insulation than those in tension. This phenomenon is related to the fact that under fire conditions, the flexural buckling coefficient in compressed members is abruptly reduced with an increase in temperature. In turn, this increase in temperature leads to a fast reduction in resistance. In addition, members in tension have much higher resistance than those in compression in the basic design situation, i.e., at the instant of t = 0 min. Consequently, even a considerable decrease in the resistance of tension members is not as dangerous as that of compression members. Therefore, due to the nature of the performance of individual elements, fire-proofing insulation of every steel structure should be computationally verified. Additionally, in this paper, the influence of the type of fire insulation on the mechanical response of the structure was investigated. Calculations were carried out for different types of sprayed-on insulation, and also for contour and box insulation panels. The graphs show the behaviour of the elastic modulus, the yield point, and the resistance of the elements in the successive minutes of the fire for the different methods of fire protection used. The best results were obtained for vermiculite and gypsum spray.
The paper presents the energy performance of a single-family house located in Domaszowice, the Kielce poviat. The analyzed object has been put into use in 2010 year. Due to the devices using non-renewable energy sources, installed in the building for the needs of hot tap water and central heating, for servicing, which human presence is necessary, two thermomodernizations were performed. The purpose of the calculations was to indicate the financial benefi ts, i.e. to reduce the costs of maintaining the home and to provide its residents with proper comfort of use of the building, bearing in mind also the health aspect. Changes have been proposed to reduce the demand for non-renewable primary energy of EP using renewable energy sources. As a result, the energy-efficient building that meets WT 2017 was obtained. The Certo 2015 program was used in the analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.