The total number of airborne micro-organisms collected on Nuclepore filters was determined by acridine orange staining and epifluorescence microscopy. The viable fraction of the total numbers varied significantly when actinomycete and fungal spores from different environments were stored on the filter surface for 1 week, although the microflora composition was not altered. A high correlation between viable and total counts was noted in environments where the airborne flora was dominated by fungal spores, while a low correlation was found for airborne bacteria. Peak values of the total counts registered in some work environments varied between 10(7) and 10(11) micro-organisms/m3. Size analysis showed a dominating fraction of respirable micro-organisms (aerodynamical diameter less than 5 micron). The investigation shows that it is of the utmost importance to combine viable counts with total count enumeration in the study of exposure to micro-organisms in work-related situations.
As a part of a worldwide investigation on the prevalence of respiratory symptoms, we have performed a study on the relationship between the indoor environment and asthma-like symptoms in the population of a central Swedish municipality. The study comprised 88 individuals, aged 20-45 years who underwent a structured interview, spirometry, a methacholine provocation test, skin-prick tests and blood samples for measurements of serum concentrations of eosinophil cationic protein (S-ECP), blood eosinophil count and total immunoglobulin E (S-IgE). In the homes, the room temperature, air humidity, respirable dust, house dust mites (HDM) and airborne micro-organisms were measured. The relative humidity in all the homes was found to be above 33%. HDM were found in 13% of homes. In the homes of the 47 subjects with asthma related symptoms, significantly higher total levels of bacteria and mould (P < 0.05) and a higher proportion of detected HDM (OR = 5.3) was found than in subjects with no asthma related symptoms, after adjustment for age, sex, smoking, indoor temperature and air humidity. HDM were found to be an independent risk factor for asthma related symptoms (OR = 7.9) and nocturnal breathlessness (OR = 6.2) (P < 0.05), while the total level of bacteria was a risk factor for asthma related symptoms and wheezing (P < 0.05). We conclude that although HDM is relatively infrequently found in the homes of central-Sweden, the presence of HDM is related to asthmatic symptoms. A relation between levels of airborne bacteria and asthma related symptoms was also found.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.