†Deceased (see In Memoriam at the end of this document) *Representative of the Pediatric and Congenital Electrophysiology Society (PACES) ‡Representative of the European Heart Rhythm Association (EHRA) xRepresentative of the Society of Thoracic Surgeons (STS) {Representative of the American College of Cardiology (ACC) #Representative of the Latin American Heart Rhythm Society (LAHRS) **Representative of the Infectious Diseases Society of America (IDSA) ‡ ‡Representative of the American Heart Association (AHA) xxRepresentative of the American Society of Anesthesiologists (ASA) {{Representative of the Asia Pacific Heart Rhythm Society (APHRS)
Disclaimer:The ESC Guidelines represent the views of the ESC and were produced after careful consideration of the scientific and medical knowledge and the evidence available at the time of their publication. The ESC is not responsible in the event of any contradiction, discrepancy, and/or ambiguity between the ESC Guidelines and any other official recommendations or guidelines issued by the relevant public health authorities, in particular in relation to good use of healthcare or therapeutic strategies. Health professionals are encouraged to take the ESC Guidelines fully into account when exercising their clinical judgement, as well as in the determination and the implementation of preventive, diagnostic, or therapeutic medical strategies; however, the ESC Guidelines do not override, in any way whatsoever, the individual responsibility of health professionals to make appropriate and accurate decisions in consideration of each patient's health condition and in consultation with that patient and, where appropriate and/or necessary, the patient's caregiver. Nor do the ESC Guidelines exempt health professionals from taking into full and careful consideration the relevant official updated recommendations or guidelines issued by the competent public health authorities, in order to manage each patient's case in light of the scientifically accepted data pursuant to their respective ethical and professional obligations. It is also the health professional's responsibility to verify the applicable rules and regulations relating to drugs and medical devices at the time of prescription.
Strategically chosen VT/VF detection and therapy parameters can safely reduce shocks and other morbidities associated with ICD therapy in patients receiving an ICD for primary prevention indications. (PREPARE-Primary Prevention Parameters Evaluation; NCT00279279).
AimsThe aim of the present study was to evaluate the relationship between left ventricular (LV) electrical delay, as measured by the QLV interval, and outcomes in a prospectively designed substudy of the SMART-AV Trial.Methods and resultsThis was a multicentre study of patients with advanced heart failure undergoing cardiac resynchronization therapy (CRT) defibrillator implantation. In 426 subjects, QLV was measured as the interval from the onset of the QRS from the surface ECG to the first large peak of the LV electrogram. Left ventricular volumes were measured by echocardiography at baseline and after 6 months of CRT by a blinded core laboratory. Quality of life (QOL) was assessed by a standardized questionnaire. When separated by quartiles based on QLV duration, reverse remodelling response rates (>15% reduction in LV end systolic volume) increased progressively from 38.7 to 68.4% and QOL response rate (>10 points reduction) increased from 50 to 72%. Patients in the highest quartile of QLV had a 3.21-fold increase (1.58–6.50, P = 0.001) in their odds of a reverse remodelling response after correcting for QRS duration, bundle branch block type, and clinical characteristics by multivariate logistic regression analysis.ConclusionElectrical dyssynchrony, as measured by QLV, was strongly and independently associated with reverse remodelling and QOL with CRT. Acute measurements of QLV may be useful to guide LV lead placement.
BACKGROUNDThe presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverterdefibrillator (ICD) that was "non-MRI-conditional" (i.e., not approved by the Food and Drug Administration for MRI scanning).
METHODSPatients in the registry were referred for clinically indicated nonthoracic MRI at a field strength of 1.5 tesla. Devices were interrogated before and after MRI with the use of a standardized protocol and were appropriately reprogrammed before the scanning. The primary end points were death, generator or lead failure, induced arrhythmia, loss of capture, or electrical reset during the scanning. The secondary end points were changes in device settings.
RESULTSMRI was performed in 1000 cases in which patients had a pacemaker and in 500 cases in which patients had an ICD. No deaths, lead failures, losses of capture, or ventricular arrhythmias occurred during MRI. One ICD generator could not be interrogated after MRI and required immediate replacement; the device had not been appropriately programmed per protocol before the MRI. We observed six cases of self-terminating atrial fibrillation or flutter and six cases of partial electrical reset. Changes in lead impedance, pacing threshold, battery voltage, and P-wave and R-wave amplitude exceeded prespecified thresholds in a small number of cases. Repeat MRI was not associated with an increase in adverse events.
CONCLUSIONSIn this study, device or lead failure did not occur in any patient with a non-MRIconditional pacemaker or ICD who underwent clinically indicated nonthoracic MRI at 1.5 tesla, was appropriately screened, and had the device reprogrammed in accordance with the prespecified protocol. (Funded by St. Jude Medical and others; MagnaSafe ClinicalTrials.gov number, NCT00907361.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.