Four groups of subjects have been investigated, using a manual phase audiometer. Group 1 consisted of 20 normal-hearing subjects. Group 2 of 22 subjects with unilateral or asymmetric cochlear hearing loss. Group 3 of 14 subjects with surgically verified CPA tumours, and Group 4 of 15 subjects with unilateral conductive impairment. In this report we suggest an upper borderline value for detecting interaural time differences of 120 microseconds. If the subject is able to detect only a value exceeding 120 microseconds, there is likely to be a retrocochlear lesion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.