In this paper the realization and optimization of two coreless open-loop bus bar current transducers based on a Hall effect sensor are presented. Two types of bus bar are evaluated: flat rectangular and rectangular with a restrictive region in the middle. Both realized transducers are capable of measuring AC and DC currents up to 300 A and 10 kHz frequency with nonlinearity less than 0.3% in the entire range. Several methods for resolving issues with the skin effect and stray magnetic fields are presented along with the experimental test results. Some of the presented methods are novel and have never been evaluated.
-This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.
Optical rotary encoders generate nonlinear sine and cosine signals in response to a change of angular position that is being measured. Due to the nonlinear shape of encoder output signals, encoder sensitivity to very small changes of angular position is low, causing a poor measurement accuracy level. To improve the optical encoder sensitivity and to increase its accuracy, an improved linearization circuit based on pseudo-linear signal generation and its further linearization with the two-stage piecewise linear analog-to-digital converter is presented in this paper. The proposed linearization circuit is composed of a mixed-signal circuit, which generates analog pseudo-linear signal and determines the first four bits of the final digital result, and the two-stage piecewise linear analog-to-digital converter, which performs simultaneous linearization and digitalization of the pseudo-linear signal. As a result, the maximal value of the absolute measurement error equals to 3.77168·10 -5 [rad] (0.00216°) over the full measurement range of 2π [rad].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.