Different aspects of hyperacute cerebral ischemia are depicted at DW and HW imaging before infarction is depicted at conventional MR or CT. These techniques may improve stroke diagnosis and may contribute to advances in treatment.
The goal of the present study is to investigate the relationship between the degree of cognitive impairment and retinal nerve fiber layer (RNFL) thickness which is measured by the optical coherence tomography (OCT). Thirty-five patients with Alzheimer's disease (AD), 35 patients with mild cognitive impairment (MCI), and 35 healthy volunteers, between the ages of 60-87, who were examined in the neurology outpatient clinic among 2012-2013 were prospectively involved in our study. Mini mental state examination (MMSE) test, montreal cognitive assessment (MOCA), and also neuropsychological test batteries were used for the neurocognitive evaluation. RNFL thickness was measured by the OCT technique and the differences among groups were studied. The relationship between RNFL thickness and MMSE scores with demographic characteristics was investigated. RNFL thickness was significantly lower in AD and MCI groups compared with the control group (p < 0.01). No significant differences of RNFL were found between the MCI and the AD groups (p > 0.05). Significant correlation was found between MMSE scores and the RNFL values (p < 0.05). Significant thinning in RNFL along with age was detected (p < 0.05). In our study, it is thought that retinal nerve fiber degeneration and central nervous system degeneration may be concurrent according to the thinning of RNFL measured by OCT in AD and MCI groups. RNFL measurement may also be useful for early diagnosis and evaluation of the disease progression. Further studies are needed to optimize the utility of this method as an ocular biomarker in AD.
In patients who develop osmotic demyelination syndrome after hemodialysis, the lesions may involve the pons or the pons and extrapontine sites. Most lesions that were followed up resolved rapidly and almost completely, favoring transient edema rather than demyelination. Blood chemistries suggested underlying changes in osmolality, particularly as a result of urea shift from the extracellular fluid.
Montreal Cognitive Assessment (MoCA) is a new cognitive tool developed for screening mild cognitive impairment (MCI). The authors examined validity of MoCA and discriminating power of subtests in a Turkish population comprising of 474 participants (246 healthy controls, 114 subjects with MCI and 114 subjects with dementia). The ANCOVAs showed that age and education had a main effect on MoCA scores. Cut scores were computed according to different education levels. The overall cut-off values for MCI and dementia were found to be lower compared to western studies. MoCA was found to have good internal consistency. The subtests most useful in discriminating MCI from healthy controls were recall, visuospatial and language, while in discriminating dementia from MCI were visuospatial, orientation and attention subtests. The results demonstrated that MoCA is a valid and reliable instrument in screening MCI, and compared with the MMSE, MoCA was proved to have superior sensitivity and specificity in detecting MCI.
Aims
Anticoagulation is not justified unless atrial fibrillation (AF) is detected in cryptogenic stroke (CS) patients. We sought to explore whether left atrial (LA) remodelling is associated with embolic stroke of undetermined source (ESUS).
Methods and results
In this prospective study, we evaluated consecutively 186 patients in sinus rhythm who presented with an acute ischaemic stroke (embolic and non-embolic) and sex- and age-matched controls. We performed continuous electrocardiogram (ECG) monitoring to capture paroxysmal AF episodes as recommended by the guidelines. After 12 months of follow-up, continuous ECG monitoring was repeated in patients with undetected AF episodes. We quantified LA reservoir and contraction strain (LASr and LASct) by speckle-tracking, LA volumes by 3D echocardiography. Out of 186 patients, 149 were enrolled after comprehensive investigation for the source of ischaemic stroke and divided into other cause (OC) (n = 52) and CS (n = 97) groups. CS patients were also subdivided into AF (n = 39) and ESUS (n = 58) groups. Among CS patients, LA strain predicted AF independently from CHARGE-AF score and LA volume indices. ESUS group, despite no captured AF, had significantly worse LA metrics than OC and control groups. AF group had the worst LA metrics. Moreover, LASr predicted both CS (embolic stroke with and without AF) and ESUS (embolic stroke with no detected AF) independently from LAVImax and CHA2DS2-VASc score. LASr >26% yielded 86% sensitivity, 92% specificity, 92% positive, and 86% negative predictive values for the identification of ESUS (areas under curve: 0.915, P < 0.0001, 95% confidence interval: 0.86–0.97).
Conclusion
Echocardiographic quantification of LA remodelling has great potential for secondary prevention from ESUS.
Doppler criteria can be both specific and sensitive for detecting a significant stenosis, defined as a < or = 1.5 mm residual lumen diameter. By adjustment of the velocity criteria, it can be 100% specific or a highly sensitive test (96%).
Although the TCD sensitivity for detecting a hemodynamically significant stenosis is relatively low, it can be highly specific (up to 100%). We conclude that TCD enhances the specificity of highly sensitive CDUS criteria for detecting a hemodynamically significant ICA stenosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.