Coded aperture imaging of fusion source in a plasma focus operated with pure D2 and a D2-Kr gas admixture Time-integrated measurements of fusion-produced protons emitted from PF-facilities AIP Conf. Proc. 812, 237 (2006); 10.1063/1.2168831 A_ measurement of S_pin-T_R_ansfer coefficients I_n the fusion reaction D_(d⃗, p⃗)3H (ASTRID) at 55 keV AIP Conf.Abstract. Protons from the fusion reactions D( 3 He,p) 4 He and D(d,p) 3 H have been observed in a small plasma focus device operated with a 3 He-D 2 gas mixture. The partial pressures of the 3 He and D 2 gasses were in the ratio of 2:1, corresponding to an atomic number ratio of 1:1. Two groups of protons with energies of approximately 16MeV and 3MeV arising from the D( 3 He,p) 4 He and D(d,p) 3 H reactions, were recorded simultaneously using a double-layer arrangement of CR-39 polymer nuclear track detectors (each of thickness 1000μm). As a result of the very different ranges of 16MeV and 3MeV protons, and the particle registration properties of CR-39, the D(d,p) 3 H protons were registered on the front-most CR-39 surface and the D( 3 He,p) 4 He protons were registered on the back-most surface of this double-layer configuration. A pinhole camera, containing the CR-39 detectors, was situated on the forward plasma focus axis in order to image the emission zones of protons for both fusion reactions. It was found that the D( 3 He,p) 4 He and D(d,p) 3 H proton yields were of similar magnitude, but their spatial distributions were very different. Results indicate that the D( 3 He,p) 4 He fusion was concentrated close to the plasma focus pinch column, while the D(d,p) 3 H fusion occurred at some distance from the pinch. Moreover, it appears that both the D( 3 He,p) 4 He and D(d,p) 3 H fusion yields are produced by beam-target mechanisms, with no significant thermonuclear contribution. To better understand the shape of the D(d,p) 3 H distribution, comparative experiments were performed with both a 4 He-D 2 gas mixture and pure D 2 gas. The D(d,p) 3 H distributions obtained for the 3 He-D 2 and 4 He-D 2 cases were found to be very similar, but markedly different from that obtained with pure D 2 gas. Possible explanations of these measured distributions are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.