Background: Positioning of the glenoid component is one of the most challenging steps in shoulder arthroplasty, and prosthesis longevity as well as functional outcomes is considered highly dependent on accurate positioning. This review considers the evidence supporting surgical navigation and patient-specific instruments for glenoid implant positioning in anatomic and reverse total shoulder arthroplasty. Methods: A systematic literature search was performed for studies assessing glenoid implant positioning accuracy as measured by cross-sectional imaging on live subjects or cadaver models. Meta-analysis of controlled studies was performed to estimate the primary effects of navigation and patient-specific instruments on glenoid implant positioning error. Meta-analysis of absolute positioning outcomes was also performed for each group incorporating data from controlled and uncontrolled studies. Results: Nine studies, four controlled and five uncontrolled, with 258 total subjects were included in the analysis. Meta-analysis of controlled studies supported that both navigation and patient-specific instruments had a moderate statistically significant effect on improving glenoid implant positioning outcomes. Meta-analysis of absolute positioning outcomes demonstrates glenoid implant positioning with standard instrumentation results in a high rate of malposition. Discussion: Navigation and patient-specific instruments improve glenoid positioning outcomes. Whether the improvement in positioning outcomes achieved translate to better clinical outcomes is unknown.
Background The Radiographic Union Score for Hip (RUSH) is a previously validated outcome instrument designed to improve intra-and interobserver reliability when describing the radiographic healing of femoral neck fractures. The ability to identify fractures that have not healed is important for defining nonunion in clinical trials and predicting patients who will likely require additional surgery to promote fracture healing. We sought to investigate the utility of the RUSH score to define femoral neck fracture nonunion. Questions/purposes (1) What RUSH score threshold yields at least 98% specificity to diagnose nonunion at 6 months postinjury? (2) Using the threshold identified, are patients below this threshold at greater risk of reoperation for nonunion and for other indications? Methods A representative sample of 250 out of a cohort of 725 patients with adequate 6-month hip radiographs was analyzed from a multinational elderly hip fracture trial (FAITH). All patients had a femoral neck fracture and were treated with either multiple cancellous screws or a sliding hip screw. Two reviewers independently determined the RUSH score based on the 6-month postinjury radiographs and interrater reliability was assessed with the interclass correlation coefficient (ICC). There was substantial reliability between the reviewers assigning the RUSH scores (ICC, 0.81; 95% confidence interval [CI], 0.76-0.85). The RUSH score is a checklist-based system that quantifies four measures of healing: cortical bridging, cortical fracture disappearance, trabecular consolidation, and trabecular fracture disappearance.. Fracture healing was determined by two independent methods: (1) concurrently by the treating surgeon using both clinical and radiographic assessments as per routine clinical care; and (2) retrospectively by a Central Adjudication Committee using complete obliteration of the fracture line on radiographs alone. Receiver operating characteristic tables were used to 123Clin Orthop Relat Res (2016) 474:1396-1404 DOI 10.1007 Clinical Orthopaedics and Related Research ® A Publication of The Association of Bone and Joint Surgeons® define a RUSH threshold score that was [ 98% specific for fracture nonunion. Results A threshold score of \ 18 was associated with a 100% specificity (95% CI, 97%-100%) and a positive predictive value of 100% (95% CI, 73%-100%) for radiographic nonunion. In contrast, using the fracture healing assessments of the treating surgeons failed to identify a useful discriminatory nonunion threshold and the highest positive predictive value was 43%. With respect to complications, patients with RUSH scores below 18 had greater risk of undergoing reoperation for nonunion ( Conclusions The 6-month RUSH score is a reliable method for assessing radiographic healing. Our results highlight the discordance between radiographic determinations and clinician assessments of fracture healing and stress the need for clinical data to be incorporated in research studies evaluating fracture healing. Level of Evidence Le...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.