The treatment of cancerous tumours in the liver remains clinically challenging, despite the wide range of treatment possibilities, including radio-frequency ablation (RFA), highintensity focused ultrasound and resection, which are currently available. Each has its own advantages and disadvantages. For non-or minimally invasive modalities, such as RFA, considered here, it is difficult to monitor the treatment in vivo. This is particularly problematic in the liver, where large blood vessels act as heat sinks, dissipating delivered heat and shrinking the size of the lesion (the volume damaged by the heat treatment) locally; considerable experience is needed on the part of the clinician to optimize the heat treatment to prevent recurrence. In this paper, we outline our work towards developing a simulation tool kit that could be used both to optimize treatment protocols in advance and to train the less-experienced clinicians for RFA treatment of liver tumours. This tool is based on a comprehensive mathematical model of bio-heat transfer and cell death. We show how simulations of ablations in two pigs, based on individualized imaging data, compare directly with experimentally measured lesion sizes and discuss the likely sources of error and routes towards clinical implementation. This is the first time that such a 'loop' of mathematical modelling and experimental validation in vivo has been performed in this context, and such validation enables us to make quantitative estimates of error.
A multi-centre retrospective study indicates that the fast RFA solver is capable of providing the IR with the predicted lesion in the short time period before the intervention begins when the patient has been clinically prepared for the treatment.
In this paper, a novel segmentation method for liver vasculature is presented, intended for numerical simulation of radio frequency ablation (RFA). The developed method is a semiautomatic hybrid based on multi-scale vessel enhancement combined with ridge-oriented region growing and skeleton-based postprocessing. In addition, an interactive tool for segmentation refinement was developed. Four instances of threephase contrast enhanced computed tomography (CT) images of porcine liver were used in the evaluation. The results showed improved accuracy over common approaches and illustrated the method's suitability for simulation purposes.
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm’s results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.
In this contribution, we present a semi-automatic segmentation algorithm for radiofrequency ablation (RFA) zones via optimal s-t-cuts. Our interactive graph-based approach builds upon a polyhedron to construct the graph and was specifically designed for computed tomography (CT) acquisitions from patients that had RFA treatments of Hepatocellular Carcinomas (HCC). For evaluation, we used twelve post-interventional CT datasets from the clinical routine and as evaluation metric we utilized the Dice Similarity Coefficient (DSC), which is commonly accepted for judging computer aided medical segmentation tasks. Compared with pure manual slice-by-slice expert segmentations from interventional radiologists, we were able to achieve a DSC of about eighty percent, which is sufficient for our clinical needs. Moreover, our approach was able to handle images containing (DSC=75.9%) and not containing (78.1%) the RFA needles still in place. Additionally, we found no statistically significant difference (p<;0.423) between the segmentation results of the subgroups for a Mann-Whitney test. Finally, to the best of our knowledge, this is the first time a segmentation approach for CT scans including the RFA needles is reported and we show why another state-of-the-art segmentation method fails for these cases. Intraoperative scans including an RFA probe are very critical in the clinical practice and need a very careful segmentation and inspection to avoid under-treatment, which may result in tumor recurrence (up to 40%). If the decision can be made during the intervention, an additional ablation can be performed without removing the entire needle. This decreases the patient stress and associated risks and costs of a separate intervention at a later date. Ultimately, the segmented ablation zone containing the RFA needle can be used for a precise ablation simulation as the real needle position is known.
The web-based Go-Smart environment is a scalable system that allows the prediction of minimally invasive cancer treatment. Interventional radiologists create a patient-specific 3D model by semi-automatic segmentation and registration of pre-interventional CT (Computed Tomography) and/or MRI (Magnetic Resonance Imaging) images in a 2D/3D browser environment. This model is used to compare patient-specific treatment plans and device performance via built-in simulation tools. Go-Smart includes evaluation techniques for comparing simulated treatment with real ablation lesions segmented from follow-up scans. The framework is highly extensible, allowing manufacturers and researchers to incorporate new ablation devices, mathematical models and physical parameters
Data below 1 mm voxel size is getting more and more common in the clinical practice but it is still hard to obtain a consistent collection of such datasets for medical image processing research. With this paper we provide a large collection of Contrast Enhanced (CE) Computed Tomography (CT) data from porcine animal experiments and describe their acquisition procedure and peculiarities. We have acquired three CE-CT phases at the highest available scanner resolution of 57 porcine livers during induced respiratory arrest. These phases capture contrast enhanced hepatic arteries, portal venous veins and hepatic veins. Therefore, we provide scan data that allows for a highly accurate reconstruction of hepatic vessel trees. Several datasets have been acquired during Radio-Frequency Ablation (RFA) experiments. Hence, many datasets show also artificially induced hepatic lesions, which can be used for the evaluation of structure detection methods.
Histological investigation of a lesion induced by radiofrequency ablation (RFA) treatment provides ground-truth about the true lesion size, thus verifying the success or failure of the RFA treatment. This work presents a framework for registration of two-dimensional large-scale histological sections and three-dimensional CT data typically used to guide the RFA intervention. The focus is on the developed interactive methods for reconstruction of the histological volume data by fusion of histological and high-resolution CT (MicroCT) data and registration into CT data based on natural feature points. The framework is evaluated using RFA interventions in a porcine liver and applying medically relevant metrics. The results of registration are within clinically required precision targets; thus the developed methods are suitable for validation of the RFA treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.