Purpose: Manufacturing of miniaturized high activity sources have been made a market preference in modern brachytherapy. Smaller dimensions of the sources are flexible for smaller diameter of the applicators, and it is also suitable for interstitial implants. Presently, cobalt-60 ( 60 Co) sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy, since 60 Co source have an advantage of longer half-life comparing with 192 Ir source. One of them is the HDR 60 Co Flexisource manufactured by Elekta. The purpose of this study was to compare the TG-43 dosimetric parameters of HDR flexi 60 Co and HDR microSelectron 192 Ir sources.Material and methods: Monte Carlo simulation code of Geant4 (v.11.0) was applied. Following the recommendations of AAPM TG-43 formalism report, Monte Carlo code of HDR flexi 60 Co and HDR microSelectron 192 Ir was validated by calculating radial dose function, anisotropy function, and dose-rate constants in a water phantom. Finally, results of both radionuclide sources were compared.Results: The calculated dose-rate constants per unit air-kerma strength in water medium were 1.108 cGy h -1 U -1 for HDR microSelectron 192 Ir, and 1.097 cGy h -1 U -1 for HDR flexi 60 Co source, with the percentage uncertainty of 1.1% and 0.2%, respectively. The values of radial dose function for distances above 22 cm for HDR flexi 60 Co source were higher than that of the other source. The anisotropic values sharply increased to the longitudinal sides of HDR flexi 60 Co source, and the rise was comparatively sharper to that of the other source.Conclusions: The primary photons from the lower-energy HDR microSelectron 192 Ir source have a limited range and are partially attenuated when considering the results of radial and anisotropic dose distribution functions. This implies that a HDR flexi 60 Co radionuclide could be used to treat tumors beyond the source compared with a HDR microSelectron 192 Ir source, despite the fact that 192 Ir has a lower exit dose than HDR flexi 60 Co radionuclide source.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.