A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.
A monolithic silicon small-field array detector is proposed for relative dosimetry applications in hybrid MRI-linac systems. The detector has high sampling resolution, with 512 active elements arranged with 2 mm pitch over a 46 mm×46 mm detection area. Experimental measurements were performed in a custom-designed permanent magnet device that is compatible with a standard clinical linear accelerator. It can be configured in both inline and perpendicular magnetic-field-to-photonbeam orientations and produces magnetic field strengths 0.95 T and 1.20 T, respectively. Monte Carlo simulation data, obtained using the GEANT4 toolkit, are presented to supplement experimental data. Beam profiles show agreement to EBT3 film within 0.5 mm for FWHM and penumbral width measurement of small square fields (width ranging from 0.75 cm to 2.25 cm), in both inline and perpendicular magnetic field orientations. The detector can be used to accurately resolve normalised beam profiles in magnetic fields. The impact of electron return effects (ERE) in a small air gap surrounding the detector was also quantified. For the perpendicular orientation, a reduced profile intensity was observed for an increasing air gap width above the detector (10% at 2 mm) due to ERE. In the inline orientation, a very small increase in response relative to the zero field case was observed with an air gap above the detector (2% at 2 mm). Calibration of the device in a magnetic field will therefore be necessary; the zero field calibration is non-transferable. The MagicPlate-512 provides a high-resolution real time alternative to accurately measure normalised beam profiles in magnetic fields, and is expected to be a suitable array detector for use in magnetic field environments typical of MRI-linacs.
Purpose The fringe field of the Australian MRI‐linac causes contaminant electrons to be focused along the central axis resulting in a high surface dose. This work aims to characterize this effect using Gafchromic film and high‐resolution detectors, MOSkinTM and microDiamond. The secondary aim is to investigate the influence of the inline magnetic field on the relative dose response of these detectors. Methods The Australian MRI‐linac has the unique feature that the linac is mounted on rails allowing for measurements to be performed at different magnetic field strengths while maintaining a constant source‐to‐surface distance (SSD). Percentage depth doses (PDD) were collected at SSD 1.82 m in a solid water phantom positioned in a low magnetic field region and then at isocenter of the MRI where the magnetic field is 1 T. Measurements for a range of field sizes were taken with the MOSkinTM, microDiamond, and Gafchromic® EBT3 film. The detectors’ relative responses at 1 T were compared to the near 0 T PDD beyond the region of electron contamination, that is, 20 mm depth. The near surface measurements inside the MRI bore were compared among the different detectors. Results Skin dose in the MRI, as measured with the MOSkinTM, was 104.5% for 2.1 × 1.9 cm2, 185.6% for 6.1 × 5.8 cm2, 369.1% for 11.8 × 11.5 cm2, and 711.1% for 23.5 × 23 cm2. The detector measurements beyond the electron contamination region showed agreement between the relative response at 1 T and near 0 T. Film was in agreement with both detectors in this region further demonstrating their relative response is unaffected by the magnetic field. Conclusions Experimental characterization of the high electron contamination at the surface was performed for a range of field sizes. The relative response of MOSkinTM and microDiamond detectors, beyond the electron contamination region, were confirmed to be unaffected by the 1‐T inline magnetic field.
This experimental work has demonstrated how strong inline magnetic fields act to enhance the dose to lower density mediums such as lung tissue. Clinically, such scenarios will arise in inline MRI-linac systems for treatment of small lung tumours.
Purpose Dose deposition measurements for parallel MRI‐linacs have previously only shown comparisons between 0 T and a single available magnetic field. The Australian MRI‐Linac consists of a magnet coupled with a dual energy linear accelerator and a 120 leaf Multi‐Leaf Collimator with the radiation beam parallel to the magnetic field. Two different magnets, with field strengths of 1 and 1.5 T, were used during prototyping. This work aims to characterize the impact of the magnetic field at 1 and 1.5 T on dose deposition, possible by comparing dosimetry measured at both magnetic field strengths to measurements without the magnetic field. Methods Dose deposition measurements focused on a comparison of beam quality (TPR20/10), PDD, profiles at various depths, surface doses, and field size output factors. Measurements were acquired at 0, 1, and 1.5 T. Beam quality was measured using an ion chamber in solid water at isocenter with appropriate TPR20/10 buildup. PDDs and profiles were acquired via EBT3 film placed in solid water either parallel or perpendicular to the radiation beam. Films at surface were used to determine surface dose. Output factors were measured in solid water using an ion chamber at isocenter with 10 cm solid water buildup. Results Beam quality was within ±0.5% of the 0 T value for the 1 and 1.5 T magnetic field strengths. PDDs and profiles showed agreement for the three magnetic field strengths at depths beyond 20 mm. Deposited dose increased at shallower depths due to electron focusing. Output factors showed agreement within 1%. Conclusion Dose deposition at depth for a parallel MRI‐linac was not significantly impacted by either a 1 or 1.5 T magnetic field. PDDs and profiles at shallow depths and surface dose measurements showed significant differences between 0, 1, and 1.5 T due to electron focusing.
PurposeTo report on experimental results of a high spatial resolution silicon‐based detector exposed to therapeutic quality proton beams in a 0.95 T transverse magnetic field. These experimental results are important for the development of accurate and novel dosimetry methods in future potential real‐time MRI‐guided proton therapy systems.MethodsA permanent magnet device was utilized to generate a 0.95 T magnetic field over a 4 × 20 × 15 cm3 volume. Within this volume, a high‐resolution silicon diode array detector was positioned inside a PMMA phantom of 4 × 15 × 12 cm3. This detector contains two orthogonal strips containing 505 sensitive volumes spaced at 0.2 mm apart. Proton beams collimated to a circle of 10 mm diameter with nominal energies of 90 MeV, 110 MeV, and 125 MeV were incident on the detector from an edge‐on orientation. This allows for a measurement of the Bragg peak at 0.2 mm spatial resolution in both the depth and lateral profile directions. The impact of the magnetic field on the proton beams, that is, a small deflection was also investigated. A Geant4 Monte Carlo simulation was performed of the experimental setup to aid in interpretation of the results.ResultsThe nominal Bragg peak for each proton energy was successfully observed with a 0.2 mm spatial resolution in the 0.95 T transverse magnetic field in both a depth and lateral profiles. The proton beam deflection (at 0.95 T) was a consistent 2 ±0.5 mm at the center of the magnetic volume for each beam energy. However, a pristine Bragg peak was not observed for each energy. This was caused by the detector packaging having small air gaps between layers of the phantom material surrounding the diode array. These air gaps act to degrade the shape of the Bragg peak, and further to this, the nonwater equivalent silicon chip acts to separate the Bragg peak into multiple peaks depending on the proton path taken. Overall, a promising performance of the silicon detector array was observed, however, with a qualitative assessment rather than a robust quantitative dosimetric evaluation at this stage of development.ConclusionsFor the first time, a high‐resolution silicon‐based radiation detector has been used to measure proton beam Bragg peak deflections in a phantom due to a strong magnetic field. Future efforts are required to optimize the detector packaging to strengthen the robustness of the dosimetric quantities obtained from the detector. Such high‐resolution silicon diode arrays may be useful in future efforts in MRI‐guided proton therapy research.
A back-projection algorithm in the presence of an extra attenuating medium: towards EPID dosimetry for the MR-Linac I Torres-Xirau, I Olaciregui-Ruiz, R A Rozendaal et al. Abstract. The Australian MRI-Linac consists of a fixed horizontal photon beam combined with a MRI. Commissioning required PDD and profiles measured in a horizontal set-up using a combination of water tank measurements and gafchromic film. To validate the methodology, measurements were performed comparing PDD and profiles measured with the gantry angle set to 0 and 90° on a conventional linac. Results showed agreement to within 2.0% for PDD measured using both film and the water tank at gantry 90° relative to PDD acquired using gantry 0°. Profiles acquired using a water tank at both gantry 0 and 90° showed agreement in FWHM to within 1 mm. The agreement for both PDD and profiles measured at gantry 90° relative to gantry 0° curves indicates that the methodology described can be used to acquire the necessary beam data for horizontal beam lines and in particular, commissioning the Australian MRI-linac.
Purpose: This study investigated the use of high spatial resolution solid-state detectors (DUO and Octa) combined with an inclinometer for machine-based quality assurance (QA) of Volumetric Modulated Arc Therapy (VMAT) with flattened and flattening filter-free beams. Method: The proposed system was inserted in the accessory tray of the gantry head of a Varian 21iX Clinac and a Truebeam linear accelerator. Mutual dependence of the dose rate (DR) and gantry speed (GS) was assessed using the standard Varian customer acceptance plan (CAP). The multi-leaf collimator (MLC) leaf speed was evaluated under static gantry conditions in directions parallel and orthogonal to gravity as well as under dynamic gantry conditions. Measurements were compared to machine log files. Results: DR and GS as a function of gantry angle were reconstructed using the DUO/inclinometer and in agreement to within 1% with the machine log files in the sectors of constant DR and GS. The MLC leaf speeds agreed with the nominal speeds and those extracted from the machine log files to within 0.03 cm s −1. The effect of gravity on the leaf motion was only observed when the leaves traveled faster than the nominal maximum velocity stated by the vendor. Under dynamic gantry conditions, MLC leaf speeds ranging between 0.33 and 1.42 cm s −1 were evaluated. Comparing the average MLC leaf speeds with the machine log files found differences between 0.9% and 5.7%, with the largest discrepancy occurring under conditions of fastest leaf velocity, lowest DR and lowest detector signal. Conclusions: The investigation on the use of solid-state detectors in combination with an inclinometer has demonstrated the capability to provide efficient and independent verification of DR, GS, and MLC leaf speed during dynamic VMAT delivery. Good agreement with machine log files suggests the detector/inclinometer system is a useful tool for machine-specific VMAT QA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.