IntroductionNeonatal jaundice is one of the most common reasons for hospital admission in low resource settings. Treatment is frequently inadequate as conventional phototherapy requires frequent bulb changes. LED phototherapy has comparable efficacy to conventional phototherapy, and the bulbs last over 40,000 hours. This observational study compares the effectiveness of three LED machines, two single-sided and one double-sided in routine use in Vietnam.MethodsWe included all infants weighting ≥1500g and with jaundice diagnosed visually or by Total Serum Bilirubin (TSB) measurement at The Da Nang Hospital for Women and Children (Da Nang, Vietnam). The primary endpoint was the average hourly change in TSB over the first six hours of treatment. The secondary endpoints were duration of treatment; average hourly change in TSB over treatment, and length of stay in the neonatal unit. Multivariable analysis and bootstrap methods was performed to compare outcomes, adjusting for potential confounders.ResultsAll outcomes were comparable in the two single-sided machines. The double-sided machine showed 54% increase in the hourly speed of TSB reduction (1.3 μmol/L/hr, 95% CI 0.3–2.3), with a 45% increase in the speed of TSB reduction over the duration of treatment (0.9 μmol/L/hr, 95% CI 0.6–1.3). In addition, the double-sided machine was associated with 21% reduction in the duration of treatment (14 hours, 95% CI 5–22) and 16% reduction of length of stay (14 hours, 95% CI 3–25).ConclusionThe results confirm and quantify the benefits of increasing surface-area exposure during phototherapy. Adjusted for multiple potential confounders, use of double-sided phototherapy can substantially increase the speed of TSB reduction, and substantially decrease the duration of treatment and length of stay in the NCU.
Our survey identified significant variations in resuscitation practices between central, provincial and district hospitals and limited adherence to international recommendations.
BackgroundInterventions to improve neonatal resuscitation are considered a priority for reducing neonatal mortality. In addition to training programs for health caregivers, the availability of adequate equipment in all delivery settings is crucial. In this study, we assessed the availability of equipment for neonatal resuscitation in a large sample of delivery rooms in Vietnam, exploring regional differences.MethodsIn 2012, a structured questionnaire on 2011 neonatal resuscitation practice was sent to the heads of 187 health facilities, representing the three levels of hospital-based maternity services in eight administrative regions in Vietnam, allowing national and regional estimates to be calculated.ResultsOverall the response rate was an 85.7 % (160/187 hospitals). There was a limited availability of equipment considered as “essential” in the surveyed centres: stethoscopes (68.0 %; 95 % CI: 60.3–75.7), clock (50.3 %; 42.0–58.7), clothes (29.5 %; (22.0–36.9), head covering (12.3 %; 7.2–17.4). The percentage of centres equipped with polyethylene bags (2.2 %; 0.0–4.6), pulse oximeter (9.4 %; 5.2–13.6) and room air source (1.9 %; 0.1–3.6) was very low.ConclusionAdequate equipment for neonatal resuscitation was not available in a considerable proportion of hospitals in Vietnam. This problem was more relevant in some regions. The assessment strategy used in this study could be useful for organizing the procurement and distribution of supplies and equipment in other low and/or middle resource settings.
BackgroundInfection causes neonatal mortality in both high and low income countries. While simple interventions to prevent neonatal infection are available, they are often poorly understood and implemented by clinicians. A basic understanding of healthcare providers' perceptions of infection control provides a platform for improving current practices. Our aim was to explore the views of healthcare providers in provincial hospitals in south and south central Vietnam to inform the design of programmes to improve neonatal infection prevention and control.MethodsAll fifty-four participants who attended a workshop on infection prevention and control were asked to complete an anonymous, written questionnaire identifying their priorities for improving neonatal infection prevention and control in provincial hospitals in south and south central Vietnam.ResultsHand washing, exclusive breastfeeding and safe disposal of medical waste were nominated by most participants as priorities for preventing neonatal infections. Education through instructional posters and written guidelines, family contact, kangaroo-mother-care, limitation of invasive procedures and screening for maternal GBS infection were advocated by a smaller proportion of participants.ConclusionsThe opinions of neonatal healthcare providers at the workshop accurately reflect some of the current international recommendations for infection prevention. However, other important recommendations were not commonly identified by participants and need to be reinforced. Our results will be used to design interventions to improve infection prevention in Vietnam, and may be relevant to other low-resource countries.
BackgroundThe most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists.Our hypothesis is based on the assumption that ventilating newborns needing positive pressure ventilation with a laryngeal mask airway will be more effective than ventilating with a face mask in a setting where neonatal resuscitation is performed by midwives, nurses, and pediatricians. The primary aim of this study will be to assess the effectiveness of the laryngeal mask airway over the face mask in preventing the need for endotracheal intubation.Methods/designThis will be an open, prospective, randomized, single center, clinical trial. In this study, 142 newborns weighing >1,500 g or delivered ≥34 weeks gestation needing positive pressure ventilation at birth will be randomized to be ventilated with a laryngeal mask airway (LMA SupremeTM, LMA Company, UK - intervention group) or with a face mask (control group). Primary outcome: Proportion of newborns needing endotracheal intubation. Secondary outcomes: Apgar score at 5 minutes, time to first breath, onset of the first cry, duration of resuscitation, death or moderate to severe hypoxic-ischemic encephalopathy within 7 days of life.Trial registrationClinicalTrials.gov identifier: NCT01963936 (October 11, 2013).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.