Digital tomosynthesis is a novel technique that allows easy and swift volume data acquisition in selected regions of the body. However, many radiologists and technologists are unfamiliar with this technique and the potential artifacts related to data acquisition. Digital tomosynthesis requires a single linear sweep of the x-ray tube assembly with corresponding tomographic reconstruction of large-area flat-panel detector radiographic data. Standard acquisition parameters include sweep angle, sweep direction, patient barrier-object distance, number of projections, and total radiation dose. Potential acquisition-related artifacts include blurring-ripple, ghost artifact-distortion, poor spatial resolution, image noise, and metallic artifact. A comprehensive understanding of the relationships between acquisition parameters and potential associated artifacts is critical to optimizing acquisition technique and avoiding misinterpretation of artifacts. Sweep direction should be chosen on the basis of the anatomy of interest and the purpose of the examination so as to reduce the influence of blurring-ripple, ghost artifact-distortion, and metallic artifact. Adjusting the sweep angle, number of projections, and radiation dose will optimize depth resolution, avoid ripple in the sections of interest, and reduce unnecessary radiation exposure without compromising image quality. Thus, it is important that the radiologist and technologist establish appropriate protocols for different examination types to allow optimal utilization of this novel imaging technique.
With flat-panel detector mammography, radiography, and fluoroscopy systems, digital tomosynthesis (DT) has been recently introduced as an advanced clinical application that removes overlying structures, enhances local tissue separation, and provides depth information about structures of interest by providing high-quality tomographic images. DT images are generated from projection image data, typically using filtered back-projection or iterative reconstruction. These low-dose x-ray projection images are easily and swiftly acquired over a range of angles during a single linear or arc sweep of the x-ray tube assembly. DT is advantageous in a variety of clinical contexts, including breast, chest, head and neck, orthopedic, emergency, and abdominal imaging. Specifically, compared with conventional mammography, radiography, and fluoroscopy, as a result of reduced tissue overlap DT can improve detection of breast cancer, pulmonary nodules, sinonasal mucosal thickening, and bone fractures and delineation of complex anatomic structures such as the ostiomeatal unit, atlantoaxial joint, carpal and tarsal bones, and pancreatobiliary and gastrointestinal tracts. Compared with computed tomography, DT offers reduced radiation exposure, better in-plane resolution to improve assessment of fine bony changes, and less metallic artifact, improving postoperative evaluation of patients with metallic prostheses and osteosynthesis materials. With more flexible patient positioning, DT is also useful for functional, weight-bearing, and stress tests. To optimize patient management, a comprehensive understanding of the clinical applications and limitations of whole-body DT applications is important for improvement of diagnostic quality, workflow, and cost-effectiveness. Online supplemental material is available for this article. (©)RSNA, 2016.
Digital tomosynthesis with flat-panel detector radiography is a novel application that allows easy, swift volume data acquisition of any anatomical site of interest with arbitrary patient posture. A single sweep of the X-ray tube provides multiple tomographic images of high resolution. We present the first patient with olecranon fracture who underwent internal fixation and 1-year postoperative follow-up with tomosynthesis. The minimal metallic artifact by this modality successfully provided detailed information regarding the healing process of the fracture.
Digital tomosynthesis allows relatively accurate detection of sinus opacification with substantial interreader agreement for all the sinuses except the ethmoid sinuses.
ObjectiveTo investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography.Materials and MethodsFor 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using κ statistics and assessing the area under the receiver operating characteristic curve (AUC).ResultsVocal cord delineation scores by DES (mean, 4.2 ± 0.4) were significantly higher than those by conventional imaging (mean, 3.3 ± 0.5) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (κ = 0.60, AUC = 0.909) to that by conventional technique (κ = 0.18, AUC = 0.852) (p = 0.038).ConclusionDual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.
DES provides better delineation of the laryngeal anatomy than conventional FPD radiography predominantly in patients with moderate-severe cervical spondylosis.
BACKGROUND: Digital radiography (DR) is grayscale adjustable and it can be unclear whether an acquired DR image is captured with the minimum radiation dose required. It is necessary to make an image of the amount of noise when taken at a lower dose than the acquired image, without increased exposure. OBJECTIVE: To examine whether an image of unacquired dose can be created from two types of dose DR images acquired using a phantom. METHODS: To create an additive image from two images of different doses, the pixel value of one image is multiplied by a coefficient and added to the other. The normalized noise power spectra (NNPS) of the normal image and the additive image with the same signal-to-noise ratio (SNR) are compared. The image noise of the unacquired doses is estimated from the graph changes of the pixel values and standard deviations of two images. The error between the SNR of the image obtained by changing the dose and the estimated SNR is measured. We propose a multiplication coefficient calculation formula that theoretically adjusts the additive image to the target SNR. The SNR error of the image created based on this formula is measured. RESULTS: The NNPS curves of the additive and normal images show a difference on the high frequency side. According to the statistics considering the preset of mAs value, there is no significant difference at 85%. The SNR estimation error is approximately 1%. The SNR error of the additive image created based on the formula is approximately 5%. CONCLUSION: The noise of the image of unacquired dose can be estimated, and the additive image adjusted to this value can be considered equivalent to the image taken at the actual dose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.