There is currently insufficient information on serum 25-hydroxyvitamin D (25OHD) and parathyroid hormone (PTH) concentrations, and bone mineral status in healthy adolescents to allow reference values to be set. This study aimed to provide comparable data on vitamin D status in Japanese adolescents and to assess sex differences in susceptibility to vitamin D insufficiency. Serum 25OHD and PTH concentrations were measured in 1,380 healthy adolescents (aged 12-18 years). Subjects completed a questionnaire on exercise history, diet, and lifestyle factors. Calcaneal stiffness was evaluated by quantitative ultrasound. Serum 25OHD concentrations in boys and girls were 60.8 ± 18.3 and 52.8 ± 17.0 nmol/L, respectively. Approximately 30 % of boys and 47 % of girls had suboptimal 25OHD concentrations (<50 nmol/L). Serum PTH concentration was negatively correlated with serum 25OHD concentration in boys, but negatively correlated with calcium intake rather than serum 25OHD in girls. In contrast, the increment in calcaneal stiffness as a result of elevation of serum 25OHD was higher in girls than in boys. As vitamin D deficiency is common in Japanese adolescents, it was estimated that intakes of ≥12 and ≥14 μg/day vitamin D would be required to reach 25OHD concentrations of 50 nmol/L in boys and girls, respectively. Moreover, the results of the present study indicate that vitamin D deficiency has a greater association with calcaneal stiffness in girls than in boys.
Background
Although automated dispensing robots have been implemented for medication dispensing in Japan, their effect is yet to be fully investigated. In this study, we evaluated the effect of automated dispensing robots and collaborative work with pharmacy support staff on medication dispensing.
Methods
A robotic dispensing system integrating the following three components was established: (1) automated dispensing robot (Drug Station®), which is operated by pharmacy support staff, (2) automated dispensing robot for powdered medicine (Mini DimeRo®), and (3) bar-coded medication dispensing support system with personal digital assistance (Hp-PORIMS®). Subsequently, we evaluated the incidences of dispensing errors and dispensing times before and after introducing the robotic dispensing system. Dispensing errors were classified into two categories, namely prevented dispensing errors and unprevented dispensing errors. The incidence of dispensing errors was calculated as follows: incidence of dispensing errors = total number of dispensing errors/total number of medication orders in each prescription.
Results
After introducing the robotic dispensing system, the total incidence of prevented dispensing errors was significantly reduced (0.204% [324/158,548] to 0.044% [50/114,111], p < 0.001). The total incidence of unprevented dispensing errors was significantly reduced (0.015% [24/158,548] to 0.002% [2/114,111], p < 0.001). The number of cases of wrong strength and wrong drug, which can seriously impact a patient’s health, reduced to almost zero. The median dispensing time of pharmacists per prescription was significantly reduced (from 60 to 23 s, p < 0.001).
Conclusions
The robotic dispensing system enabled the process of medication dispensing by pharmacist to be partially and safely shared with automated dispensing robots and pharmacy support staff. Therefore, clinical care for patients by pharmacists could be enhanced by ensuring quality and safety of medication.
BackgroundAmiodarone and warfarin are sometimes administered immediately after cardiac surgery. Although the interaction between long-term oral amiodarone and warfarin has been reported, the interaction between warfarin and short-term intravenous amiodarone has not been reported. In this study, we investigated the effect of short-term intravenous amiodarone on the anticoagulant effect of warfarin in patients who underwent cardiac surgery.MethodsWe retrospectively reviewed the medical records of 11 patients who received oral warfarin before and after cardiac surgery, and loading doses of 125–150 mg or a 750 mg continuous infusion of amiodarone, or both in the intensive care unit (ICU) within 5 days after the surgery between July 2011 and January 2017. The prothrombin time-international normalized ratio (PT-INR)/daily warfarin dose (PT-INR/dose) was used as an indicator of anticoagulant effect. The values before surgery were considered as the baseline.ResultsThe PT-INR and PT-INR/dose values were elevated in 7 and 10 patients, respectively, after amiodarone administration. The mean PT-INR values were not significantly different before and after amiodarone administration (2.13 ± 0.58 vs 2.29 ± 0.50, respectively, p = 0.643). In contrast, the mean PT-INR/dose values were significantly elevated after the administration of amiodarone (0.93 ± 0.46 vs 1.54 ± 0.63, respectively, p = 0.002).ConclusionsShort-term intravenous amiodarone enhanced the anticoagulant effect of warfarin in patients admitted to the ICU after cardiac surgery. We suggest that the dose of warfarin should be carefully adjusted for a few days after cardiac surgery if intravenous amiodarone is coadministered.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.