Because of the increasing use of maize hybrids with genetically modified (GM) stacked events, the established and commonly used bulk sample methods for PCR quantification of GM maize in non-GM maize are prone to overestimate the GM organism (GMO) content, compared to the actual weight/weight percentage of GM maize in the grain sample. As an alternative method, we designed and assessed a group testing strategy in which the GMO content is statistically evaluated based on qualitative analyses of multiple small pools, consisting of 20 maize kernels each. This approach enables the GMO content evaluation on a weight/weight basis, irrespective of the presence of stacked-event kernels. To enhance the method's user-friendliness in routine application, we devised an easy-to-use PCR-based qualitative analytical method comprising a sample preparation step in which 20 maize kernels are ground in a lysis buffer and a subsequent PCR assay in which the lysate is directly used as a DNA template. This method was validated in a multilaboratory collaborative trial.
To reduce the cost and time required to routinely perform the genetically modified organism (GMO) test, we developed a duplex quantitative real-time PCR method for a screening analysis simultaneously targeting an event-specific segment for GA21 and Cauliflower Mosaic Virus 35S promoter (P35S) segment [Oguchi et al., J. Food Hyg. Soc. Japan, 50, 117ῌ125 (2009)]. To confirm the validity of the method, an interlaboratory collaborative study was conducted. In the collaborative study, conversion factors (Cfs), which are required to calculate the GMO amount (῍), were first determined for two real-time PCR instruments, the ABI PRISM 7900HT and the ABI PRISM 7500. A blind test was then conducted. The limit of quantitation for both GA21 and P35 S was estimated to be 0.5῍ or less. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSD R ). The determined bias and RSD R were each less than 25῍. We believe the developed method would be useful for the practical screening analysis of GM maize.
Qualitative PCR methods for the genetically modified (GM) maize events MON810, Bt11, and GA21, and the 35S promoter (P35S) region of the cauliflower mosaic virus (CaMV) were evaluated in an interlaboratory study. Real-time PCR-based quantitative methods for these GM events using the same primer pairs had already been validated in previous studies. Fifteen laboratories in Japan participated in this interlaboratory study. Each participant extracted DNA from blind samples, performed qualitative PCR assays, and then detected the PCR products with agarose gel electrophoresis. The specificity, sensitivity, and false-negative and false-positive rates of these methods were determined with different concentrations of GM mixing samples. LODs of these methods for MON810, Bt11, GA21, and the P35S segment calculated as the amount of MON810 were 0.2, 0.2, 0.1, and 0.2% or less, respectively, indicating that the LODs of MON810, Bt11, and P35S were lower than 10 copies, and the LOD of GA21 was lower than 25 copies of maize haploid genome. The current study demonstrated that the qualitative methods would be fit for the detection and identification of these GM maize events and the P35S segment.
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event; A2704-12. During the plant transformation, DNA fragments derived from pUC19 plasmid were integrated in A2704-12, and the region was found to be A2704-12 specific. The pUC19-derived DNA sequences were used as primers for the specific detection of A2704-12. We first tried to construct a standard plasmid for A2704-12 quantification using pUC19. However, non-specific signals appeared with both qualitative and quantitative PCR analyses using the specific primers with pUC19 as a template, and we then constructed a plasmid using pBR322. The conversion factor (C f ), which is required to calculate the amount of the genetically modified organism (GMO), was experimentally determined with two real-time PCR instruments, the Applied Biosystems 7900HT and the Applied Biosystems 7500. The determined C f values were both 0.98. The quantitative method was evaluated by means of blind tests in multi-laboratory trials using the two real-time PCR instruments. The limit of quantitation for the method was estimated to be 0.1῍. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSD R ), and the determined bias and RSD R values for the method were each less than 20῍. These results suggest that the developed method would be suitable for practical analyses for the detection and quantification of A2704-12.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.