The paper presents results of comparative analyses of optical signals generated by corona discharges occurring in the vicinity and on the surface of power transmission lines made of five different materials under laboratory conditions. Three aluminium-based materials were chosen: pure aluminium, aluminium with added magnesium, and aluminium with added silicon, and for comparison purposes also, steel-based lines were considered: copper-coated steel and steel with added chromium and nickel. A three-phase triangular arrangement system operating under maximal voltage equal to 110 kV was applied for experimental tests. The optical radiation was registered using a spectrophotometer. During research works, also the influence of corona generation voltage and distance between power lines was investigated. Based on the achieved results, it was stated that the highest corona intensity was found for aluminium-based lines, for both pure aluminium and aluminium with added magnesium and silicon. The lowest corona intensity was observed for chromium- and nickel-alloyed (stainless) steel.
The paper presents results of comparative analysis of optical signals emitted by partial discharges occurring on three types of high voltage insulators made of porcelain. The research work consisted of diagnosis of the following devices: a long rod insulator, a cap insulator, and an insulating cylinder. For optical signal registration a spectrophotometer was applied. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage. For the cylindrical insulator also the distance between high voltage and ground electrodes was subjected for investigation as a factor having influence on partial discharges. The main contribution which resulted from the studies is statement that application of spectrophotometer enables faster recognition of partial discharges, as compared to standard methods.
Abstract. The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.