<p><em>Measurement of Peak Particle Velocity (PPV) mm / sec in the Sabo dam construction project was carried out using seismic accelerometers. This study is to determine the value of PPV produced by construction equipment and then compared with the BS 6472-2: 2008 standard. The measurement method is carried out based on the applicable rules. PPV measurement results produced by each machine are different. In heavy equipment dump trucks, excavators, and front end loaders show PPV values at distances of 50 m, 100 m, 150 m and 200 m under safe conditions referring to the standard which is still in the range of 0.2 - 0.4 mm / sec. while for the pile driving device, demolition, vibrator pile driver at a distance of 50 meters are in unsafe conditions, because more than the range of 0.2 - 0.4 mm / sec, but at a distance of 100, 150, and 200 m PPV values are at safe condition</em></p><p><em><br /></em></p><p>Key words<strong>: </strong><em>PPV, Ground Vibration, Dam sabo</em></p><p><strong> </strong></p><p><em><br /></em></p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.