In our lipopolysaccharide model, with resuscitation targeted at blood pressure, contrast-enhanced ultrasound imaging can identify renal microvascular alterations by showing prolonged contrast enhancement in microcirculation during shock, worsened by resuscitation with fluids. Concomitant analysis of sublingual microcirculation mirrored those observed in the renal microcirculation.
Ultrasound contrast agents (UCA) consist of gas‐filled coated microbubbles with diameters of 1–10 µm. Targeted UCA can bind to biomarkers associated with disease through coating‐incorporated ligands, making ultrasound molecular imaging possible. The aim of our research was to compare the ligand distribution, binding area, and bound microbubble shape of 1,2‐distearoyl‐sn‐glycero‐3‐phosphocholine (DSPC) based and 1,2‐dipalmitoyl‐sn‐glycero‐3‐phosphocholine (DPPC) based lipid‐coated microbubbles using super‐resolution microscopy. Ligand distribution was studied by conjugating the fluorescent streptavidin Oregon Green 488 to the biotinylated microbubbles. An inhomogeneous streptavidin distribution was found when DSPC was the main coating lipid. When DSPC was replaced by DPPC, a more homogeneous streptavidin distribution was observed. Binding area of targeted microbubbles was studied using biotinylated microbubbles bound to a streptavidin‐coated surface. DSPC microbubbles had a significantly smaller binding area than DPPC microbubbles. Whereas the bound DSPC microbubbles remained spherical, the DPPC microbubbles were dome‐shaped. This study reveals that lipid‐coated microbubbles differ in ligand distribution, binding area, and bound microbubble shape solely on the basis of their main lipid component. Practical applications: A homogeneous ligand distribution, larger binding area and domed shape upon binding could be advantageous for binding of targeted microbubbles, thereby favoring DPPC over DSPC as main lipid for UCA for ultrasound molecular imaging. The findings of the present study can be used for the design of targeted microbubbles with improved binding capabilities and for the ongoing research to acoustically distinguish bound from unbound microbubbles. Targeted biotinylated DSPC and DPPC‐based microbubbles bound to streptavidin‐coated surface. Left graph: binding area; right panels: microbubbles (red fluorescent) bound to streptavidin‐coated surface (green fluorescent).
BACKGROUND Cardiac troponin T (cTnT) is widely used for the diagnosis of acute myocardial infarction (AMI). However, it is still unclear whether degraded cTnT forms circulate in the patient's blood. We therefore aimed to elucidate which cTnT forms are detected by the clinical assay. METHODS Separation of cTnT forms by gel filtration chromatography (GFC) was performed in sera from 13 AMI patients to examine cTnT degradation. The GFC eluates were subjected to Western blot analysis with the original antibodies from the Roche immunoassay used to mimic the clinical cTnT assay. To investigate the degradation pattern with time, standardized serum samples of 18 AMI patients collected 0–72 h after admission were analyzed by Western blot analysis. RESULTS GFC analysis of AMI patients' sera revealed 2 cTnT peaks with retention volumes of 5 and 21 mL. Western blot analysis identified these peaks as cTnT fragments of 29 and 14–18 kDa, respectively. Furthermore, the performance of direct Western blots on standardized serum samples demonstrated a time-dependent degradation pattern of cTnT, with fragments ranging between 14 and 40 kDa. Intact cTnT (40 kDa) was present in only 3 patients within the first 8 h after hospital admission. CONCLUSIONS These results demonstrate that the Roche cTnT immunoassay detects intact as well as degraded cTnT forms in AMI patients' sera during the period of diagnostic testing. Moreover, following AMI, cTnT is degraded in a time-dependent pattern.
Ultrasound contrast agents (UCAs) are used routinely in the clinic to enhance contrast in ultrasonography. More recently, UCAs have been functionalised by conjugating ligands to their surface to target specific biomarkers of a disease or a disease process. These targeted UCAs (tUCAs) are used for a wide range of pre-clinical applications including diagnosis, monitoring of drug treatment, and therapy. In this review, recent achievements with tUCAs in the field of molecular imaging, evaluation of therapy, drug delivery, and therapeutic applications are discussed. We present the different coating materials and aspects that have to be considered when manufacturing tUCAs. Next to tUCA design and the choice of ligands for specific biomarkers, additional techniques are discussed that are applied to improve binding of the tUCAs to their target and to quantify the strength of this bond. As imaging techniques rely on the specific behaviour of tUCAs in an ultrasound field, it is crucial to understand the characteristics of both free and adhered tUCAs. To image and quantify the adhered tUCAs, the state-of-the-art techniques used for ultrasound molecular imaging and quantification are presented. This review concludes with the potential of tUCAs for drug delivery and therapeutic applications.
Phospholipid-coated targeted microbubbles are ultrasound contrast agents that can be used for molecular imaging and enhanced drug delivery. However, a better understanding is needed of their targeting capabilities and how they relate to microstructures in the microbubble coating. Here, we investigated the ligand distribution, lipid phase behavior, and their correlation in targeted microbubbles of clinically relevant sizes, coated with a ternary mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) or 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), with PEG40-stearate and DSPE-PEG2000. To investigate the effect of lipid handling prior to microbubble production in DSPC-based microbubbles, the components were either dispersed in aqueous medium (direct method) or first dissolved and mixed in an organic solvent (indirect method). To determine the lipid-phase behavior of all components, experiments were conducted on monolayers at the air/water interface. In comparison to pure DSPC and DPPC, the ternary mixtures had an additional transition plateau around 10–12 mN/m. As confirmed by infrared reflection absorption spectroscopy (IRRAS), this plateau was due to a transition in the conformation of the PEGylated components (mushroom to brush). While the condensed phase domains had a different morphology in the ternary DPPC and DSPC monolayers on the Langmuir trough, the domain morphology was similar in the coating of both ternary DPPC and DSPC microbubbles (1.5–8 μm diameter). The ternary DPPC microbubbles had a homogenous ligand distribution and significantly less liquid condensed (LC) phase area in their coating than the DSPC-based microbubbles. For ternary DSPC microbubbles, the ligand distribution and LC phase area in the coating depended on the lipid handling. The direct method resulted in a heterogeneous ligand distribution, less LC phase area than the indirect method, and the ligand colocalizing with the liquid expanded (LE) phase area. The indirect method resulted in a homogenous ligand distribution with the largest LC phase area. In conclusion, lipid handling prior to microbubble production is of importance for a ternary mixture of DSPC, PEG40-stearate, and DSPE-PEG2000.
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of CF and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter ~1 [Formula: see text]) than sonication (number weighted mean diameter ~2 [Formula: see text]). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available Target-Ready MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney ( n = 7 ), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.