OBJECTIVES--To compare the pullout properties of 3.5-mm AO/ASIF self-tapping screws (STS) to corresponding standard cortex screws (CS) in a uniform synthetic test material and in canine femoral bone. The influence of screw-insertion technique, test material, and test-material thickness were also assessed. STUDY DESIGN--In vitro experimental study. SAMPLE POPULATION--Two independent studies: a uniform synthetic test material and paired femurs from mature dogs. METHODS-Mechanical testing was performed in accordance with standards established by the American Society for Testing and Materials for determination of axial pullout strength of medical bone screws. Completely inserted STS, completely inserted CS, and incompletely inserted STS were tested in 3 groups of 10 test specimens each in 4.96-mm and 6.8-mm thick sheets of synthetic material. In the bone study, group 1 consisted of 24 completely inserted STS compared with 24 completely inserted CS, and group 2 consisted of 24 incompletely inserted STS versus 24 completely inserted CS. Comparisons were made between paired femurs at corresponding insertion sites. Pullout data were normalized, thereby eliminating the effect of test-material thickness on pullout properties. Mean values were compared using 2-way ANOVA. Statistical significance was set at P <.05. RESULTS--In both the 4.96-mm and 6.8-mm synthetic material, pullout testing of the completely inserted STS demonstrated significantly greater yield strength and ultimate strength than completely inserted CS. There was no significant difference between incompletely inserted STS and completely inserted STS. The 6.8-mm test material significantly increased yield strength and ultimate strength for all test groups compared with the 4.96-mm test material. In canine bone, there was no significant difference in yield strength of completely inserted STS and completely inserted CS. Yield strength of completely inserted STS and completely inserted CS were significantly greater than incompletely inserted STS. CONCLUSIONS--Pullout properties of completely inserted STS were significantly greater than corresponding CS in a uniform test material. In canine bone, the pullout strength of STS and CS were not different. Incomplete STS insertion resulted in an 18% reduction in holding power as compared with completely inserted CS and STS in canine bone. CLINICAL RELEVANCE--The length of STS used in canine bone should be such that the cutting flutes extend beyond the trans cortex to maximize pullout strength.
E ducators are placing a greater emphasis on the development of cooperative laboratory experiences that supplement the traditional lecture format. The new laboratory materials should encourage active learning, problem-solving, and inquiry-based approaches. To address these goals, we developed a laboratory exercise designed to introduce students to the hemodynamic variables (heart rate, stroke volume, total peripheral resistance, and compliance) that alter arterial pressure. For this experience, students are presented with ''unknown'' chart recordings illustrating pulsatile arterial pressure before and in response to several interventions. Students must analyze and interpret these unknown recordings and match each recording with the appropriate intervention. These active learning procedures help students understand and apply basic science concepts in a challenging and interactive format. Furthermore, laboratory experiences may enhance the students' level of understanding and ability to synthesize and apply information. In conducting this exercise, students are introduced to the joys and excitement of inquiry-based learning through experimentation.
differences demonstrated were for the middle trapezius during internal rotation activities. Conclusions: All subjects with rotator cuff tears demonstrated significantly increased muscle activation as a percentage of MVC when compared to normal subjects for many, but not all muscles throughout a variety of functional tasks. During elevation and internal rotation tasks, asymptomatic subjects were not different than the normal controls for the upper trapezius and supraspinatus, while the symptomatic subjects had increases in the activation of the upper trapezius, middle trapezius and a paradoxical increase in the firing of the torn supraspinatus. As all subjects with rotator cuff tears demonstrated abnormal muscle activation, differential muscle activation alone cannot account for the clinical variability of symptoms and function between symptomatic and asymptomatic patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.