Revisions after total joint replacement increase constantly. In the current study, we analyzed clinical outcome, complication rates, and cost-effectiveness of revision arthroplasty. In a retrospective analysis of 162 revision hip and knee arthroplasties from our institutional joint registry responder rate, patient-reported outcome measures (EQ-5D, WOMAC), complication rates, and patient-individual charges in relation to reimbursement were compared with a matched control group of primary total joint replacements. Positive responder rate one year postoperatively was lower for revision arthroplasties with 72.9% than for primary arthroplasties with 90.1% (OR=0.30, 95%CI=0.18–0.59, p=0.001). Correspondingly, improvement in patient-reported outcome measures one year after surgery was lower in revision than in primary joint arthroplasty with EQ-5D 0.19±0.25 to 0.30±0.24 (p<0.001) and WOMAC 24.3±30.3 to 41.2±21.3 (p<0.001). Infection rate was higher in revision (6.8%) compared to primary replacements (0%, p=0.001). Mean charges in revision arthroplasty were 76.0% higher than in matched primary joint replacements (7110.8±2249.4$ to 4041.1±975.7$, p<0.001), whereas reimbursement was only 23.6% higher (9243.3±2258.4$ in revision and 7477.9±703.1$ in primary arthroplasty, p<0.001). Revision arthroplasty is associated with lower outcome and higher infection rate compared to primary replacements. The high financial expense of revision arthroplasty is only partly covered by a higher reimbursement.
Background and purposeAdequate restoration of femoral offset (FO) is critical for successful outcome after hip arthroplasty or fixation of hip fracture. Previous studies have identified that hip rotation influences the projected femoral offset (FOP) on plain anteroposterior (AP) radiographs, but the precise effect of rotation is unknown.Patients and methodsWe developed a novel method of assessing rotation-corrected femoral offset (FORC), tested its clinical application in 222 AP hip radiographs following proximal femoral nailing, and validated it in 25 cases with corresponding computed tomography (CT) scans.ResultsThe mean FORC was 57 (29–93) mm, which differed significantly (p < 0.001) from the mean FOP 49 (22–65) mm and from the mean femoral offset determined by the standard method: 49 (23–66) mm. FORC correlated closely with femoral offset assessed by CT (FOCT); the Spearman correlation coefficient was 0.94 (95% CI: 0.88–0.97). The intraclass correlation coefficient for the assessment of FORC by AP hip radiographs correlating the repeated measurements of 1 observer and of 2 independent blinded observers was 1.0 and 1.0, respectively.InterpretationHip rotation affects the FOP on plain AP radiographs of the hip in a predictable way and should be adequately accounted for.
We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.