Short circuit causing over current problem and can might causing interference of the equipment performance such as distribution transformers also causing widespread disruption occurred. In resolving such interference is required as protection system on the distribution system. Seeing all above is needed coordination between the supporting component of the protection system which is consisted of Over Current Relay (OCR) and Ground Fault Relay (GFR). The research was conducted at PT. PLN (Persero) South Bali Area Network, INDONESIA on recloser in the feeder line of Penebel. OCR setting between the Relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana still less selective, with time value coordination between average security was still less than 0,2 second. Then OCR setting and GFR relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana was recommended for re-setting in order to minimize disruption and electric power distribution system to be reliable.
The increasing need for electrical power with a stable and continuous distribution ofelectricity networks is an absolute requirement in meeting the needs of electrical energy. Theload imbalance between each phase (phase R, phase S, and phase T) which flows a net currentin the transformer, because of the transformer tolerance set by PLN, which is 20% of the powercapacity of the transformer In Abiansemal feeders there is a load imbalance of more than 20 %then in this study the load balancing is carried out in the LVMDV panel on three-phasecustomers, which has an impact on the load imbalance between each phase (phase R, phaseS, and phase T) which causes a neutral current and causes losses (losses). Based on thisproblem, balancing must be done by measuring first. From the measurement results in theLVMDP panel on three-phase customers and data obtained from the results of measurement ofload imbalance during the day is 29.9% and 26.6 % and the load imbalance at night is 62.6%and 31%, as shown in Table 4.5, it can be seen that the bush on the large current neutral INthat flows in the transformer neutral conductor, the greater the loss in the neutral conductor(PN).
Renewable energy is energy that comes from natural processes that will not be exhausted and sustainable if managed properly. In its use, to maintain the continuity of the availability of electrical energy maximally, it is necessary to combine several types of power plants that are connected to the grid or better known as hybrid grid connected power systems. This research took place at Villa Peruna Saba, Gianyar - Bali which uses a hybrid grid connected power system that combines photovoltaics and generators connected to the grid utilty in supplying electricity loads. The analysis is carried out on the characteristics of the average load, the contribution of each electric power source and the workings of the hybrid grid connected hybrid power plant system. From the analysis, it is known that the contribution of power derived from solar power plants is 561.27 kW or 22.41% in April 2018 and 510.72 kW or 20.71% in May 2018.
In an effort to increase electricity supply PT PLN (Persero) build GIS Tanah Lot in Nyitdah Village Tabanan regency. The new GIS development makes the network transmission system High Voltage Air Line 150 kV changed. Changes in this transmission system impact on the channel safety settings due to changes in transmission length and impedance value. Prior to the analysis of the impedance setting, the Distance Relay Distance Zone with current, working time and OCR Relay coordination (Over Current Relay) firstly analyzes short circuit flows two phases and three symmetric phases using ETAP PowerStation program. After calculation of distance relation setting, the value of channel impedance in Tanah Lot GIS is 2,4 + j 6,96 ? with Zone 1 setting (80%): 0,200 + j 0,588 ?, Zone 2 (120%): 0,30 + j 0.882 ?, and Zone 3 (220%): 0.68 + j 2.30 ?. OCR (Over Current Relay) release time setting is indicated by releasing delay (tD>) for Tanah Lot GIS - Antosari and Tanah Lot GIS - The vessel has a value of 0.48 with an actual working time release of 1.134 seconds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.