Recent studies demonstrate neuropathic changes with respect to vibration sensitivity for different measurement frequencies. This study investigates the relationship between vibration perception thresholds (VPTs) at low and high frequencies at two plantar locations and diabetic peripheral neuropathy (DPN) severity in diabetes mellitus (DM) subjects with DPN. We examine differences of VPTs between participants with DM, with DPN, as well as healthy controls. The influence of anthropometric, demographic parameters, and DM duration on VPTs is studied. Thirty-three healthy control group subjects (CG: 56.3 ± 9.9 years) and 33 with DM are studied. DM participants are subdivided into DM group (DM without DPN, n = 20, 53.3 ± 15.1 years), and DPN group (DM with DPN, n = 13, 61.0 ± 14.5 years). VPTs are measured at the first metatarsal head (MTH1) and heel (30 Hz, 200 Hz), using a customized vibration exciter. Spearman and Pearson correlations are used to identify relationships between VPTs and clinical parameters. ANOVAs are calculated to compare VPTs among groups. Significant correlations are observed between DPN severity (by fuzzy scores) and VPTs at both locations and frequencies (MTH1_30 Hz vs. fuzzy: r = 0.68, p = 0.011; Heel_30 Hz vs. fuzzy: r = 0.66, p = 0.014; MTH1_200 Hz vs. fuzzy: r = 0.73, p = 0.005; Heel_200 Hz vs. fuzzy: r = 0.60, p = 0.032). VPTs in CG and DM groups are significantly smaller than the DPN group, showing higher contrasts for the 30 Hz compared to the 200 Hz measurement. The correlations between fuzzy scores and VPTs confirm the relevance of using low and high frequencies to assess a comprehensive foot sensitivity status in people with DM.
Mechanical skin properties (MSPs) and vibration perception thresholds (VPTs) show no relationship in healthy subjects. Similar results were expected when comparing MSP and VPT in individuals with diabetes mellitus (DM) and with diabetic (peripheral-)neuropathy (DPN). A healthy control group (33 CG), 20 DM and 13 DPN participated in this cross-sectional study. DM and DPN were classified by using a fuzzy decision support system. VPTs (in µm) were measured with a modified vibration exciter at two different frequencies (30 and 200 Hz) and locations (heel, first metatarsal head). Skin hardness (durometer readings) and thickness (ultrasound) were measured at the same locations. DPN showed the highest VPTs compared to DM and CG at both frequencies and locations. Skin was harder in DPN compared to CG (heel). No differences were observed in skin thickness. VPTs at 30 and 200 Hz correlated negatively with skin hardness for DPN and with skin thickness for DM, respectively. This means, the harder or thicker the skin, the better the perception of 30 or 200 Hz vibrations. Changes in MSP may compensate the loss of sensitivity up to a certain progression of the disease. However, the influence seems rather small when considering other parameters, such as age.
Subliminal electrical noise (SEN) enhances sensitivity in healthy individuals of various ages. Diabetes and its neurodegenerative profile, such as marked decreases in foot sensitivity, highlights the potential benefits of SEN in such populations. Accordingly, this study aimed to investigate the effect of SEN on vibration sensitivity in diabetes. Vibration perception thresholds (VPT) and corresponding VPT variations (coefficient of variation, CoV) of two experimental groups with diabetes mellitus were determined using a customized vibration exciter (30 and 200 Hz). Plantar measurements were taken at the metatarsal area with and without SEN stimulation. Wilcoxon signed-rank and t tests were used to test for differences in VPT and CoV within frequencies, between the conditions with and without SEN. We found no statistically significant effects of SEN on VPT and CoV (p > 0.05). CoV showed descriptively lower mean variations of 4 and 7% for VPT in experiment 1. SEN did not demonstrate improvements in VPT in diabetic individuals. Interestingly, taking into account the most severely affected (neuropathy severity) individuals, SEN seems to positively influence vibratory perception. However, the descriptively reduced variations in experiment 1 indicate that participants felt more consistently. It is possible that the effect of SEN on thick, myelinated Aβ-fibers is only marginally present.
Diabetes mellitus is one of the most frequent diseases in the general population. Electrical stimulation is a treatment modality based on the transmission of electrical pulses into the body that has been widely used for improving wound healing and for managing acute and chronic pain. Here, we discuss recent advancements in electroceuticals and haptic/smart devices for quality of life and present in which patients and how electrical stimulation may prove to be useful for the treatment of diabetes-related complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.