Following injury of a complementary joint restraint, ligaments can be subjected to higher than normal stresses. Normal ligaments are exposed to static (creep) and cyclic (fatigue) loading from which damage can accumulate at these higher than normal stresses. This study tracked damage accumulation during creep and fatigue loading of normal rabbit medial collateral ligaments (MCLs) over a range of stresses, using modulus reduction as a marker of damage. Creep tests were interrupted occasionally with unloading/reloading cycles to measure modulus. Test stresses were normalized to ultimate tensile strength (UTS): 60%, 30%, and 15% UTS. Not all creep and fatigues tests progressed until rupture but were stopped and followed by an assessment of the residual strength of that partially damaged ligament using a monotonic failure test. Fatigue loading caused earlier modulus reduction than creep. Modulus reduction occurred at lower increases in strain (strain relative to initial strain) for fatigue than creep. In other words, at the same time or increase in strain, fatigue is more damaging than creep because the modulus ratio reduction is greater. These findings suggest that creep and fatigue have different strain and damage mechanisms. Ligaments exposed to creep or fatigue loading which produced a modulus reduction had decreased residual strength and increased toe-region strain in a subsequent monotonic failure test. This finding confirmed that modulus reduction during creep and fatigue is a suitable marker of partial damage in ligament. Cyclic loading caused damage earlier than static loading, likely an important consideration when ligaments are loaded to higher than normal magnitudes following injury of a complementary joint restraint.
Purpose Adjacent level degeneration that occurs above and/or below long fusion constructs is a documented clinical problem that is widely believed to be associated with the considerable change in stiffness caused by the fusion. Some researchers have suggested that early degeneration at spinal joints adjacent to a fusion could be treated by implanting total disc replacements at these levels. It is thought that further degeneration could be prevented through the disc replacement's design aims to reproduce normal disc heights, kinematics and tissue loading. For this reason, there is a clinical need to evaluate if a total disc replacement can maintain both the quantity of motion (i.e. range) and the quality of motion (i.e. center of rotation and coupling) at segments adjacent to a long spinal fusion. The purpose of this study was to experimentally evaluate range of motion (ROM-the intervertebral motion measured) and helical axis of motion (HAM) changes due to one-and two-level Maverick total disc replacement (TDR) adjacent to a long spinal fusion. Methods Seven spine specimens (T8-S1) were used in this study (66 ± 19 years old, 3F/4 M). A continuous pure moment of ±5.0 Nm was applied to the specimen in flexion-extension (FE), lateral bending (LB) and axial rotation (AR), with a compressive follower preload of 400 N. The 5.0 Nm data were analyzed to evaluate the operated segment biomechanics at the level of the disc replacements. The data were also analyzed at lower moments using a modified version of Panjabi's proposed ''hybrid'' method to evaluate adjacent segment kinematics (intervertebral motion at the segments adjacent to the fusion) under identical overall (T8-S1) specimen rotations. The motion of each vertebra was monitored with an optoelectronic camera system. The biomechanical test was completed for (1) the intact condition and repeated after each surgical technique was applied to the specimen, (2) capsulotomy at L4-L5 and L5-S1, (3) T8-L4 fusion and capsulotomy at L4-L5 and L5-S1, (4) Maverick at L4-L5, and (5) Maverick at L5-S1. The capsulotomy was performed to allow measurement of facet joint loads in a companion study. Paired t tests were used to determine if differences in the kinematic parameters measured were significant. Holm-Sidak corrections for multiple comparisons were applied where appropriate. replacement (mean = 22 %, compared to the fused condition). Two-level Maverick implantation also tended to reduce L4-S1 ROM (mean 18, 7 and 31 % in FE, LB and AR, respectively, compared to the fused condition without TDR). Following TDR replacement, the HAM location tended to shift posteriorly in FE (at L5-S1), anteriorly in AR, and inferiorly in LB. However, although the abovementioned trends were observed, neither one-nor two-level TDR replacement showed statistically significant ROM or HAM change in any of the three directions. At the identical T8-S1 posture identified by the modified hybrid analysis, the L4-L5 and L5-S1 levels underwent significant larger motions, relative to the overall speci...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.