The purpose of the study was to estimate the reliability of whole-body impedance cardiography (ICGWB)-derived pulse wave velocity (PWV) and stroke volume index to pulse pressure (SI/PP) measurements. The repeatability and reproducibility of ICGWB parameters were also determined. Agreement between the impedance and Doppler ultrasound-based PWV measurements was estimated in 25 healthy subjects in two consecutive measurements. Impedance-derived SI/PP (SIICG/PP) estimates were compared with simultaneously measured SI/PP based on thermodilution (SITD/PP) and direct Fick (SIFICK/PP) methods in 30 surgical patients. PWV measured between the aortic arch and popliteal artery using the impedance technique with selective electrode configuration (PWVIS) agreed well with the Doppler ultrasound method (PWVDOPP), the bias (PWVDOPP - PWVIS) and precision (+/- SD of differences) being 0.00 and 0.79 m s-1, respectively. PWV derived from the whole-body and popliteal impedance plethysmograms (PWVICG) overestimated slightly PWVDOPP values. The repeatability value for PWVIS was excellent, being 0.54 m s-1. The reproducibility values for PWVDOPP and PWVIS were very similar (2.17 and 2.42 m s-1, respectively). Changes in PWVIS correlated strongly with changes in PWVDOPP (r=0.74; P<0.0001), indicating that both methods reflected the true physiological variation in PWV. The agreement between SIICG/PP and SITD/PP or SIFICK was almost identical to the agreement between the SITD/PP and SIFICK/PP. In conclusion,whole-body impedance cardiography provides handy and reliable means of evaluating arterial stiffness on the basis of PWV and SI/PP simultaneously with conventional haemodynamic parameters. The method is highly repeatable and reproducible.
IP significantly reduced postoperative VF/VT in patients with CABG with 3-vessel disease. Suppression of VT during early reperfusion and 24 hours after reperfusion suggests early and delayed IP phenomena in patients undergoing CABG surgery.
Postcoronary artery bypass grafting atrial fibrillation is associated with more complicated postoperative outcome. Higher preoperative heart rate and postoperative pulmonary capillary wedge pressure were the independent predictors of atrial fibrillation. Recent unstable angina is not related to the occurrence of postcoronary artery bypass grafting atrial fibrillation. Ischemic preconditioning significantly suppresses postcoronary artery bypass grafting atrial fibrillation, suggesting that ischemic preconditioning can be used as an effective prophylactic method for postoperative atrial fibrillation.
The present findings show that cardiac autonomic regulation is impaired after CABG. Nonlinear HRV exponent alpha1 is a more sensitive measure to predict the postoperative outcome in CABG patients. IP alleviates the extreme autonomic reactions after surgery, suggesting that cardiac autonomic regulation is involved in the IP protective mechanism.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.