The pattern of lung response caused by intravenous Mch and Ova are fundamentally different. Although inhaled Mch induces a heterogeneous lung response similar to that observed with intravenous allergen, these similar patterns are due to different mechanisms.
Electrical stimulation of intercostal muscles was employed to measure thoracic gas volume (TGV) during airway occlusion in the absence of respiratory effort at different levels of lung inflation. In 15 tracheostomized and mechanically ventilated CBA/Ca mice, the value of TGV obtained from the spontaneous breathing effort available in the early phase of the experiments (TGVsp) was compared with those resulting from muscle stimulation (TGVst) at transrespiratory pressures of 0, 10, and 20 cmH2O. A very strong correlation (r2= 0.97) was found, although with a systematically (approximately 16%) higher estimation of TGVst relative to TGVsp, attributable to the different durations of the stimulated (approximately 50 ms) and spontaneous (approximately 200 ms) contractions. Measurements of TGVst before and after injections of 0.2, 0.4, and 0.6 ml of nitrogen into the lungs in six mice resulted in good agreement between the change in TGVst and the injected volume (r2= 0.98). In four mice, TGVsp and TGVst were compared at end expiration with air or a helium-oxygen mixture to confirm the validity of isothermal compression in the alveolar gas. The TGVst values measured at zero transrespiratory pressure in all CBA/Ca mice [0.29 +/- 0.05 (SD) ml] and in C57BL/6 (N = 6; 0.34 +/- 0.08 ml) and BALB/c (N = 6; 0.28 +/- 0.06 ml) mice were in agreement with functional residual capacity values from previous studies in which different techniques were used. This method is particularly useful when TGV is to be determined in the absence of breathing activity, when it must be known at any level of lung inflation or under non-steady-state conditions, such as during pharmaceutical interventions.
A tracking impedance estimation technique was developed to follow the changes in total respiratory impedance (Zrs) during slow total lung capacity maneuvers in six anesthetized and mechanically ventilated BALB/c mice. Zrs was measured with the wave-tube technique and pseudorandom forced oscillations at nine frequencies between 4 and 38 Hz during inflation from a transrespiratory pressure of 0-20 cmH2O and subsequent deflation, each lasting for approximately 20 s. Zrs was averaged for 0.125 s and fitted by a model featuring airway resistance (Raw) and inertance, and tissue damping and elastance (H). Lower airway conductance (Glaw) was linearly related to volume above functional residual capacity (V) between 0 and 75-95% maximum V, with a mean slope of dGlaw/dV = 13.6 +/- 4.6 cmH2O-1. s-1. The interdependence of Raw and H was characterized by two distinct and closely linear relationships for the low- and high-volume regions, separated at approximately 40% maximum V. Comparison of Raw with the highest-frequency resistance of the total respiratory system revealed a marked volume-dependent contribution of tissue resistance to total respiratory system resistance, resulting in the overestimation of Raw by 19 +/- 8 and 163 +/- 40% at functional residual capacity and total lung capacity, respectively, whereas the lowest frequency reactance was proportional to H; these findings indicate that single-frequency resistance values may become inappropriate as surrogates of Raw when tissue impedance is changing.
The lack of an LPR, limited EPR and the absence of a link between the LPR and AHR highlight the limitations of this mouse model as a complete model of the lung dysfunction associated with asthma.
Absolute lung volumes such as functional residual capacity, residual volume (RV), and total lung capacity (TLC) are used to characterize emphysema in patients, whereas in animal models of emphysema, the mechanical parameters are invariably obtained as a function of transrespiratory pressure (Prs). The aim of the present study was to establish a link between the mechanical parameters including tissue elastance (H) and airway resistance (Raw), and thoracic gas volume (TGV) in addition to Prs in a mouse model of emphysema. Using low-frequency forced oscillations during slow deep inflation, we tracked H and Raw as functions of TGV and Prs in normal mice and mice treated with porcine pancreatic elastase. The presence of emphysema was confirmed by morphometric analysis of histological slices. The treatment resulted in an increase in TGV by 51 and 44% and a decrease in H by 57 and 27%, respectively, at 0 and 20 cmH(2)O of Prs. The Raw did not differ between the groups at any value of Prs, but it was significantly higher in the treated mice at comparable TGV values. In further groups of mice, tracheal sounds were recorded during inflations from RV to TLC. All lung volumes but RV were significantly elevated in the treated mice, whereas the numbers and size distributions of inspiratory crackles were not different, suggesting that the airways were not affected by the elastase treatment. These findings emphasize the importance of absolute lung volumes and indicate that tissue destruction was not associated with airway dysfunction in this mouse model of emphysema.
The double sigmoidal nature of the mouse pressure-volume (PV) curve is well recognized but largely ignored. This study systematically examined the effect of inflating the mouse lung to 40 cm H2O transrespiratory pressure (Prs) in vivo. Adult BALB/c mice were anesthetized, tracheostomized, and mechanically ventilated. Thoracic gas volume was calculated using plethysmography and electrical stimulation of the intercostal muscles. Lung mechanics were tracked during inflation-deflation maneuvers using a modification of the forced oscillation technique. Inflation beyond 20 cm H2O caused a shift in subsequent PV curves with an increase in slope of the inflation limb and an increase in lung volume at 20 cm H2O. There was an overall decrease in tissue elastance and a fundamental change in its volume dependence. This apparent "softening" of the lung could be recovered by partial degassing of the lung or applying a negative transrespiratory pressure such that lung volume decreased below functional residual capacity. Allowing the lung to spontaneously recover revealed that the lung required approximately 1 h of mechanical ventilation to return to the original state. We propose a number of possible mechanisms for these observations and suggest that they are most likely explained by the unfolding of alveolar septa and the subsequent redistribution of the fluid lining the alveoli at high transrespiratory pressure.
Understanding the fluorescence of complex systems such as small nanocrystals with various surface terminations in solution is still a scientific challenge. Here we show that the combination of advanced time-resolved spectroscopy and ab initio simulations, aided by surface engineering, is able to 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 2 identify the luminescence centers of such complex systems. Fluorescent water soluble silicon carbide (SiC) nanocrystals have been previously identified as complex molecular systems of silicon, carbon, oxygen and hydrogen held together by covalent bonds that made the identification of their luminescence centers unambiguous. The aqueous solutions of molecular-sized SiC nanocrystals are exceedingly promising candidates to realize bioinert non-perturbative fluorescent nanoparticles for in vivo bioimaging, thus the identification of their luminescent centers is of immediate interest. Here we present identification of two emission centers of this complex system: surface groups involving carbon -oxygen bonds and a defect consisting of silicon -oxygen bonds which becomes the dominant pathway for radiative decay after total reduction of the surface. The identification of these luminescent centers reconciles previous experimental results on the surface and pH dependent emission of SiC nanocrystals and helps design optimized fluorophores and nanosensors for in vivo bioimaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.