Mutations of fibrillin-1 (FBN1) have been associated with Marfan syndrome and pleiotropic connective tissue disorders, collectively termed as "type I fibrillinopathy".However, few genotype-phenotype correlations are known in the ocular system.Patients with congenital ectopia lentis (EL) received panel-based next-generation sequencing, complemented with multiplex ligation-dependent probe amplification.In a total of 125 probands, the ocular phenotypes were compared for different types of FBN1 mutations. Premature termination codons were associated with less severe EL and a thinner central corneal thickness (CCT) than the inframe mutations. The eyes of patients with mutations in the C-terminal region had a higher incidence of posterior staphyloma than those in the middle and N-terminal regions. Mutations in the TGF-β-regulating sequence had larger horizontal corneal diameters (white-towhite [WTW]), higher incidence of posterior staphyloma, but less severe EL than those with mutations in other regions. Mutations in the neonatal region were associated with thinner CCT. Longer axial length (AL) was associated with mutations in the C-terminal region or TGF-β regulating sequence after adjusting for age, EL severity, and corneal curvature radius. FBN1 genotype-phenotype correlations were established for some ocular features, including EL severity, AL, WTW, CCT, and so forth, providing novel perspectives and directions for further mechanistic studies.
<b><i>Introduction:</i></b> Marfan syndrome (MFS) is characterized by ectopia lentis (EL) and elongated axial length (AL). The characteristics of AL in young patients with MFS and bilateral EL before the lens surgery are not fully understood. <b><i>Methods:</i></b> This study reviewed MFS patients under 20 years old with bilateral EL from January 2015 to October 2020. The Z-scores were introduced in terms of the number of standard deviations from the mean of age-matched normative data. Using Z-scores, the distribution of AL and influence factors were evaluated. The correlations between AL and other biometrics were analyzed. <b><i>Results:</i></b> We reviewed 183 patients and enrolled both eyes. The mean age was 8.44 ± 4.69 years. About 36% of the patients were children under 6 years old. The median AL increased from 23.16 mm under 5 years old to 26.20 mm in the 16–20 age group, and when plotted, the trend presented a logarithmic curvature (<i>R</i><sup>2</sup> = 0.145, <i>p</i> < 0.001). The median Z-AL score was 1.24. One-third of eyes had Z-score <0. About 20% of the patients had AL difference over 1 mm between the right and left eyes, and the right one had longer Z-AL scores (<i>p</i> = 0.013). The eye complicated with megalocornea (10, 7.04%) had larger Z-AL scores (4.72 ± 3.51 vs. 1.10 ± 2.25, <i>p</i> = 0.002). A positive correlation was found between Z-AL and Z-corneal curvature radius (<i>r</i> = 0.265, <i>p</i> < 0.001). <b><i>Conclusion:</i></b> Young patients with bilateral EL but small AL should not be excluded from MFS without systematic examination. The age-adjusted Z-score will facilitate further study of the individual variations in AL across different ages.
BackgroundMicrospherophakia (MSP) is a rare ocular condition, the lens surgery of which is complicated by both insufficient zonules and undersized capsule.MethodsThis study included MSP eyes managed with phacoemulsification combined with supra-capsular and scleral-fixated intraocular lens implantation (SCSF-IOL) and made the comparison with those treated by transscleral-fixated modified capsular tension ring and in-the-bag intraocular lens implantation (MCTR-IOL).ResultsA total of 20 MSP patients underwent SCSF-IOL, and 17 patients received MCTR-IOL. The postoperative best corrected visual acuity was significantly improved in both groups (P < 0.001), but no difference was found between the groups (P = 0.326). The IOL tilt was also comparable (P = 0.216). Prophylactic Nd:YAG laser posterior capsulotomy was performed 1 week to 1 month after the SCSF-IOL procedure. In the SCSF-IOL group, two eyes (10.00%) needed repeated laser treatment and one eye (5.00%) had a decentered capsule opening. Posterior capsule opacification was the most common complication (6, 35.29%) in the MCTR group. No IOL dislocation, secondary glaucoma, or retinal detachment was observed during follow-up.ConclusionsSCSF-IOL is a viable option for managing MSP and is comparable with the MCTR-IOL. Nd:YAG laser posterior capsulotomy was necessary to prevent residual capsule complications after the SCSF-IOL procedure.
AIM: To investigate whether the axial length (AL)/total corneal refractive power (TCRP) ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome (MFS) in children. METHODS: The relationship between the AL/TCRP ratio and the diagnosis of MFS for 192 eyes in 97 children were evaluate. The biological characteristics, including age, sex, AL, and TCRP, were collected from medical records. Receiver operating characteristic (ROC) curve analysis was performed to investigate whether the AL/TCRP ratio effectively distinguishes MFS from other subjects. The Youden index was used to re-divide the whole population into two groups according to an AL/TCRP ratio of 0.59. RESULTS: Of 96 subjects (mean age 7.46±3.28y) evaluated, 56 (110 eyes) had a definite diagnosis of MFS in childhood based on the revised Ghent criteria, 41 (82 eyes) with diagnosis of congenital ectopia lentis (EL) were included as a control group. AL was negatively correlated with TCRP, with a linear regression coefficient of -0.36 (R2=0.08). A significant correlation was found between age and the AL/TCRP ratio (P=0.023). ROC curve analysis showed that the AL/TCRP ratio distinguished MFS from the other patients at a threshold of 0.59. MFS patients were present in 24/58 (41.38%) patients with an AL/TCRP ratio of ≤0.59 and in 34/39 (87.18%) patients with an AL/TCRP ratio of >0.59. CONCLUSION: An AL/TCRP ratio of >0.59 is significantly associated with the risk of MFS. The AL/TCRP ratio should be measured as a promising marker for the prognosis of children MFS. Changes in the AL/TCRP ratio should be monitored over time.
ObjectiveThe aim of this study was to examine the biometric ocular manifestations and structural ocular features of anterior megalophthalmos (AM).MethodsFifteen patients with AM (30 eyes) from the Eye & ENT Hospital of Fudan University were included. The age-matched control group consisted of 30 participants (30 eyes) who underwent Pentacam HR and IOLMaster 700 measurements for one normal eye. Data on demographics, biometric manifestations, and genotypes were carefully compared.ResultsA total of 15 patients with AM and 30 control patients were enrolled. There were no differences in age (37.27 ± 19.1 vs. 31.43 ± 19.69 years, P = 0.249) between these two groups. AM eyes were characterized by premature cataracts (11/30, 36.67%) and zonular weakness with lens subluxation (22/30, 73.33%) compared with the control group. Notably, 20 of the 30 AM eyes (66.67%) had significant posterior iris bowing, and 16 of the 30 AM eyes (53.33%) showed an enlarged ciliary ring on ultrasound biomicroscopy (UBM). Mean corneal curvature was lower in the AM eyes (42.01 ± 2.06 D vs. 43.14 ± 1.38 D, P = 0.023). There was no significant difference in corneal pachymetry and central endothelial cell count between the AM and control groups. Significant differences were found in terms of the anterior chamber and white-to-white (WTW) among the Pentacam HR and IOLMaster 700 in patients with AM (P < 0.05). The difference was 0.53 ± 0.48 mm and 0.36 ± 0.14 mm, respectively (P < 0.001).ConclusionThe results of this cohort study conclude the biometric and structural ocular manifestations in Chinese cohorts. Posterior iris bowing (66.67%) and lens subluxation (73.33%) are the most characteristic findings in patients with AM with anatomical abnormalities of megalocornea and a deep anterior chamber, although corneal biometric manifestations of AM included flatter cornea and lower total corneal astigmatism. The knowledge of ocular manifestations of AM is important for diagnosis and preparation for the operation in advance to avoid intraoperative and postoperative complications. Significant differences were found in the anterior chamber and WTW values between the Pentacam HR and IOLMaster 700. Thus, we suggest that various examinations should be carefully considered before determining an AM diagnosis.
Introduction: This is a cross-sectional cohort study focused on assessing the influence of ocular biometric parameters of different camera devices for accurately predicting the intraocular lens (IOL) power in the congenital ectopia lentis (EL) patients. Methods: This study includes a total of 91 eyes of 60 patients with congenital EL from June 2018 to April 2021. All patients underwent lens subluxation surgery with Cionni modified capsular tension rings (MCTR) implantation. Ocular parameters measured by partial coherence interferometry (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany) and rotating Scheimpflug camera (Pentacam HR system, Oculus Optikgeräte GmbH, Wetzlar, Germany) were acquired from the database. The authenticity of the different keratometries (K) were analyzed by comparing the prediction error in spherical equivalent under controlled formula SRK/T, Haigis, and after Wang-Koch (WK) adjustment. Results: We observed significant greater K values were obtained in IOLMaster than Pentacam, resulting in more significant hyperopia error while calculating SRK/T. The IOL power calculated with the total corneal refractive power (TCRP) from Pentacam revealed the highest prediction accuracy, indicating that TCRP is the closest to the actual refractive power of the cornea. However, in an exceptional case for long eye patients, total keratometry from IOLMaster was better recommended when using formula Haigis with WK adjustment. Conclusions: For most instances, TCRP is the best-recommended source of K value while calculating IOL power for EL patients. However, the total keratometry from IOLMaster preferably fits for long eye patients, who require WK adjustment for Haigis formula.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.