Time-varying magnetic fields can be used to transfer power across the skin to drive implantable biomedical devices without the use of percutaneous wires. However, the main challenges of a transcutanoues energy transfer (TET) system are the temperature rise caused by power loss in the implanted circuitry and the changes in positioning between the external and internal coils due to fitting and changes in posture. This study presents a TET system with a closed-loop frequency-based power regulation method to deliver the right amount of power to the load under variable coil coupling conditions. After implanting a TET system into adult sheep, the temperature rise in the internal and external coils of a TET system was measured for power delivery in the range of 5 W to 15 W. The sheep was housed in a temperature controlled (16 plusmn1degC, humidity 50plusmn10%) room, in accordance with the standard protocols implemented at the University of Auckland for sheep studies. A power-loss analysis for the overall system was performed. The system was capable of regulating power for axially aligned separations of up to 16 mm. The maximum power efficiency of the overall system was 82.1% and a maximum temperature rise of 2.7degC was observed on the implanted secondary coil.
Transcutaneous energy transfer (TET) systems use magnetic fields to transfer power across the skin without direct electrical connectivity. This offers the prospect of lifetime operation and overcomes risk of infection associated with wires passing through the skin. Previous attempts at this technology have not proved suitable due to poor efficiency, large size, or tissue damage. We have developed a novel approach utilizing frequency control that allows for wide tolerance in the alignment between internal and external coils for coupling variations of 10 to 20 mm, and relatively small size (50 mm diameter, 5 mm thickness). Using a sheep experimental model, the secondary coil was implanted under the skin in six sheep, and the system was operated to deliver a stable power output to a 15 W load continuously over 4 weeks. The maximum surface temperature of the secondary coil increased by a mean value of 3.4 +/- 0.4 degrees C (+/-SEM). The highest absolute mean temperature was 38.3 degrees C. The mean temperature rise 20 mm from the secondary coil was 0.8 +/- 0.1 degrees C. The efficiency of the system exceeded 80% across a wide range of coil orientations. Histological analysis revealed no evidence of tissue necrosis or damage after four weeks of operation. We conclude that this technology is able to offer robust transfer of power to implantable devices without excess heating causing tissue damage.
Transcutaneous energy transfer (TET) enables the transfer of power across the skin without direct electrical connection. It is a mechanism for powering implantable devices for the lifetime of a patient. For maximum power transfer, it is essential that TET systems be resonant on both the primary and secondary sides, which requires considerable design effort. Consequently, a strong need exists for an efficient method to aid the design process. This paper presents an analytical technique appropriate to analyze complex TET systems. The system's steady-state solution in closed form with sufficient accuracy is obtained by employing the proposed equivalent small parameter method. It is shown that power-transfer capability can be correctly predicted without tedious iterative simulations or practical measurements. Furthermore, for TET systems utilizing a current-fed push-pull soft switching resonant converter, it is found that the maximum energy transfer does not occur when the primary and secondary resonant tanks are "tuned" to the nominal resonant frequency. An optimal turning point exists, corresponding to the system's maximum power-transfer capability when optimal tuning capacitors are applied.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.