Background: Polycaprolactone (PCL) is a synthetic aliphatic polyester widely used in biomedical applications with biodegradability in the body and promotes cell proliferation and differentiation. A newly developed bilayered PCL membrane was developed for possibly being used as a membrane in guided bone regeneration (GBR).Purpose: To compare the clinical efficacy between a newly developed bilayered PCL membrane with a Cytoplast™ RTM collagen membrane for GBR with simultaneous implant placement.Materials and Methods: Twenty-four patients were randomized to PCL or RTM group, and a total of 24 dental implants were placed. Primary outcomes were patient mean buccal bone thickness (BBT) immediately postimplantation and at 6 months using cone-beam CT and soft tissue surface dimensional changes (STC) at crown insertion, 6 months, and 1 year after loading using intraoral scanner. Secondary outcomes included success rate, clinical parameters, healing index, implant stability, pink esthetic score, and marginal bone levels.Results: The percentage of reduced BBT at 6 months was 32.38%, 25.94%, and 23.96% in the test group and 34.42%, 14.75%, and 6.34% in the control group at the corresponding levels. The mean difference of changed BBT associated with PCL membrane, when compared to collagen membrane, at 6 months was À0.02 ± 0.18 mm (95% confidence interval [CI]: À0.40 to 0.35), 0.29 ± 0.28 mm (95% CI: À0.29 to 0.87), and 0.62 ± 0.38 mm (95% CI: À0.17 to 1.42) at 0, 2, and 4 mm from implant shoulder. Minimal loss of STC was observed in both groups up to 1 year of loading. The mean difference loss of surface dimensional change associated with PCL membrane, when compared to collagen membrane, at 1 year of loading was 0.31 ± 0.19 mm (95% CI: À0.07 to 0.70), 0.22 ± 0.26 mm (95% CI: À0.33 to 0.76), and 0.17 ± 0.30 mm (95% CI: À0.45 to 0.78) at 0, 2, and 4 mm from implant shoulder. None of these differences were statistically significant (unpaired t-test, degrees of freedom [df] = 22; p > 0.05). Conclusion:Within the limits of this trial, both barrier membranes resulted in comparable outcomes for GBR with implant placement after 1 year in function. Further research is necessary with a larger sample size.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.