Summary The purpose of this study was to evaluate a new method of internal fixation technique for pastern arthrodesis. Pastern arthrodeses are performed commonly in horses with chronic osteoarthritis of the pastern joint or, in cases of acute traumatic injury to the pastern, in which the weightbearing bony column must be restored. Chronic osteoarthritis of the pastern is a frequent cause of lameness in the equine athlete and is evidenced by chronic lameness localised to the pastern joint, and supported radiographically by periosteal proliferation and loss of joint space. Nonsurgical and surgical treatments have both been described in the literature. Complications following pastern arthrodesis have been reported on several occasions and appear to focus on excessive periarticularexostoses and increased time in a cast due to prolonged time to bony fusion. The hospital records of horses presenting for pastern arthrodesis to the Rood and Riddle Equine Hospital in Lexington, Kentucky, were reviewed and 22 met criteria for inclusion in the study. Horses with chronic osteoarthritis of the proximal interphalangeal joint or horses with an acute traumatic injury to the pastern undergoing pastern arthrodesis with one of the following techniques were included in the study. Horses with severe comminution of the middle phalanx were excluded. Three 5.5 mm cortical bone screws placed in lag fashion alone or in combination with a 4 or 3 hole dynamic compression plate affixed with 4.5 mm cortical bone screws were compared. A lower limb fibreglass cast was applied in all cases. Period in cast, time to return to intended use, complications encountered and outcome were evaluated. Seven of the 8 hindlimbs treated with the combination technique became sound. Three out of 6 of the front limbs treated with the combination technique became sound. Four of the 5 horses with hindlimbs, and one of the 2 with front limbs, treated with screws only returned to their intended use. The type of internal fixation did not appear to influence the overall number of horses returning to the intended level of performance. The period spent in cast and the time to return to soundness were decreased in horses operated on using the combination technique. We concluded that, in the immediate postoperative period, the combination of the parallel screw technique with a dorsally‐applied dynamic compression plate provides the most stable and secure fixation, minimising motion, expediting bone remodelling and therefore favouring rapid fusion of that joint.
The leading cause of treatment failure in Staphylococcus aureus infections is the development of biofilms. Biofilms are highly tolerant to conventional antibiotics which were developed against planktonic cells. Consequently, there is a lack of antibiofilm agents in the antibiotic development pipeline. To address this problem, we developed a platelet-rich plasma (PRP)-derived biologic, termed BIO-PLY (for the BIOactive fraction of Platelet-rich plasma LYsate) which has potent in vitro bactericidal activity against S. aureus synovial fluid free-floating biofilm aggregates. Additional in vitro studies using equine synoviocytes and chondrocytes showed that BIO-PLY protected these cells of the joint from inflammation. The goal of this study was to test BIO-PLY for in vivo efficacy using an equine model of infectious arthritis. We found that horses experimentally infected with S. aureus and subsequently treated with BIO-PLY combined with the antibiotic amikacin (AMK) had decreased bacterial concentrations within both synovial fluid and synovial tissue and exhibited lower systemic and local inflammatory scores compared to horses treated with AMK alone. Most importantly, AMK+BIO-PLY treatment reduced the loss of infection-associated cartilage proteoglycan content in articular cartilage and decreased synovial tissue fibrosis and inflammation. Our results demonstrate the in vivo efficacy of AMK+BIO-PLY and represents a new approach to restore and potentiate antimicrobial activity against synovial fluid biofilms.
Spectral CT has been increasingly implemented clinically for its better characterization and quantification of materials through its multi-energy results. It also facilitates calculation of physical density, allowing for non-invasive mass measurements and temperature evaluations by manipulating the definition of physical density and thermal volumetric expansion, respectively. To develop spectral physical density quantifications, original and parametrized Alvarez–Macovski model and electron density-physical density model were validated with a phantom. The best physical density model was then implemented on clinical spectral CT scans of ex vivo bovine muscle to determine the accuracy and effect of acquisition parameters on mass measurements. In addition, the relationship between physical density and changes in temperature was evaluated by scanning and subjecting the tissue to a range of temperatures. The parametrized Alvarez–Macovski model performed best in both model development and validation with errors within ± 0.02 g/mL. No effect from acquisition parameters was observed in mass measurements, which demonstrated accuracy with a maximum percent error of 0.34%. Furthermore, physical density was strongly correlated (R of 0.9781) to temperature changes through thermal volumetric expansion. Accurate and precise spectral physical density quantifications enable non-invasive mass measurements for pathological detection and temperature evaluation for thermal therapy monitoring in interventional oncology.
Bacterial contamination of an exposed implantable medical device by the atmosphere of an operating room (OR) is increasingly implicated as a cause of device‐associated infection. Here, OR contamination is modeled in vitro using an aerosolizing system to spray small quantities of staphylococci onto titanium rods. Contaminated rods always manifest culturable bacteria. Self‐assembly is used to create a self‐defensive Ti surface that substantially enhances the rod's resistance to such contamination. Poly(acrylic acid) microgels are electrostatically deposited onto small Ti rods and subsequently loaded by complexation with a cationic antimicrobial peptoid (TM1). The microgels are visualized in situ by optical microscopy, and changes in microgel diameter indicate the loading state. These measurements show that TM1 can be quickly loaded from low‐ionic‐strength buffer and subsequently remained sequestered within the microgels for up to 4 weeks when soaked in phosphate buffered saline. TM1‐loaded microgel‐modified Ti surfaces are contaminated with aerosolized staphylococci, and subsequent assays indicate few or no culturable bacteria. In the absence of nutrients to enable metabolism, this finding suggests that bacteria trigger local TM1 release by contact transfer. The modified surfaces exhibit good in vitro cytocompatibility as manifested by the adhesion, spreading, and metabolic activity of human fetal osteoblasts.
Background Nuclectomy, also known as nucleotomy, is a percutaneous surgical procedure performed to remove nucleus material from the center of the disc. Multiple techniques have been considered to perform a nuclectomy, however, the advantages and disadvantages of each are not well understood. Aims This in vitro biomechanical investigation on human cadaveric specimens aimed to quantitatively compare three nuclectomy techniques performed using an automated shaver, rongeurs, and laser. Material & Methods Comparisons were made in terms of mass, volume and location of material removal, changes in disc height, and stiffness. Fifteen vertebra–disc–vertebra lumbar specimens were acquired from six donors (40 ± 13 years) and split into three groups. Before and after nucleotomy axial mechanical tests were performed and T2‐weighted 9.4T MRIs were acquired for each specimen. Results When using the automated shaver and rongeurs similar volumes of disc material were removed (2.51 ± 1.10% and 2.76 ± 1.39% of the total disc volume, respectively), while considerably less material was removed using the laser (0.12 ± 0.07%). Nuclectomy using the automated shaver and rongeurs significantly reduced the toe‐region stiffness (p = 0.036), while the reduction in the linear region stiffness was significant only for the rongeurs group (p = 0.011). Post‐nuclectomy, 60% of the rongeurs group specimens showed changes in the endplate profile while 40% from the laser group showed subchondral marrow changes. Discussion From the MRIs, homogeneous cavities were seen in the center of the disc when using the automated shaver. When using rongeurs, material was removed non‐homogeneously both from the nucleus and annulus regions. Laser ablation formed small and localized cavities suggesting that the technique is not suitable to remove large volumes of material unless it is developed and optimized for this application. Conclusion The results demonstrate that both rongeurs and automated shavers can be used to remove large volumes of NP material but the reduced risk of collateral damage to surrounding tissues suggests that the automated shaver may be more suitable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.