The flexible pressure sensor is one of the essential components of the wearable device, which is a critical solution to the applications of artificial intelligence and human−computer interactions in the future. Due to its simple manufacturing process and measurement methods, research related to piezoresistive mechanical sensors is booming, and those sensors are already widely used in industry. However, existing pressure sensors are almost all based on negative resistance variations, making it difficult to reach a balance between the sensitivity and the detection range. Here, we demonstrated a low-cost flexible pressure sensor with a positive resistance−pressure response based on laser scribing graphene. The sensor can be customized and modulated to achieve both an ultrahigh sensitivity and a broad detection range. Furthermore, the device possesses the signal amplification property like a mechanical triode under the external pressure bias. Based on its amplification ability, varieties of physiological signals and human movements have been detected using our devices; then, an integrated gait monitoring system has been realized. The reported positive graphene pressure sensor has outstanding capability, showing a wide application range such as intelligent perception, an interactive device, and real-time health/motion monitoring.
Based on the good characteristics of graphene, many physiological signals can be detected by graphene sensors covering the human body. Graphene wearable sensors have great potential in healthcare and telemedicine.
Intraocular pressure (IOP) is the prime indicator for the diagnosis and treatment of glaucoma. IOP has circadian rhythm changes and is dependent on body gestures; therefore, a single measurement in the clinic can be misleading for diagnosis. Herein, few-layer graphene is utilized to develop non-invasive sensors with high transparency, sensitivity, linearity, and biocompatibility for 24 h continuous IOP monitoring. The graphene Wheatstone bridge consisting of two strain gauges and two compensating resistors is designed to improve the sensitivity and accuracy of IOP measurement. Testing results on a silicone eyeball indicate that the output voltage of the sensor is proportional to the IOP fluctuation. Under the various ranges and speeds of IOP fluctuation, the sensor exhibits excellent performance of dynamic cycles and step responses with an average sensitivity of 150 μV/mmHg. With the linear relationship, the average relative error between the calibrated IOP and the standard pressure is maintained at about 5%. More than 100 cycles and interval time measurements illustrate that the sensor possesses significant stability, durability, and reliability. Furthermore, a wireless system is designed for the sensor to realize IOP monitoring using a mobile phone. This sensor, with the average transparency of 85% and its ease of fabrication, as well as its portability for continuous IOP monitoring, brings new promise to the diagnosis and treatment of glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.