High-performance electromagnetic interference (EMI) shielding materials with ultralow density, excellent flexibility, and good mechanical properties are highly desirable for aerospace and wearable electronics. Herein, honeycomb porous graphene (HPG) fabricated by laser scribing technology is reported for EMI shielding and wearable applications. Due to the honeycomb structure, the HPG exhibits an EMI shielding effectiveness (SE) up to 45 dB at a thickness of 48.3 μm. The single-piece HPG exhibits an ultrahigh absolute shielding effectiveness (SSE/t) of 240 123 dB cm 2 /g with an ultralow density of 0.0388 g/cm 3 , which is significantly superior to the reported materials such as carbon-based, MXene, and metal materials. Furthermore, MXene and AgNWs are employed to cover the honeycomb holes of the HPG to enhance surface reflection; thus, the SSE/t of the HPG/AgNWs composite membrane can reach up to 292 754 dB cm 2 /g. More importantly, the HPG exhibits excellent mechanical stability and durability in cyclic stretching and bending, which can be used to monitor weak physiological signals such as pulse, respiration, and laryngeal movement of humans. Therefore, the lightweight and flexible HPG exhibits excellent EMI shielding performance and mechanical properties, along with its low cost and ease of mass production, which is promising for practical applications in EMI shielding and wearable electronics.
With the aging of society and the increase in people’s concern for personal health, long-term physiological signal monitoring in daily life is in demand. In recent years, electronic skin (e-skin) for daily health monitoring applications has achieved rapid development due to its advantages in high-quality physiological signals monitoring and suitability for system integrations. Among them, the breathable e-skin has developed rapidly in recent years because it adapts to the long-term and high-comfort wear requirements of monitoring physiological signals in daily life. In this review, the recent achievements of breathable e-skins for daily physiological monitoring are systematically introduced and discussed. By dividing them into breathable e-skin electrodes, breathable e-skin sensors, and breathable e-skin systems, we sort out their design ideas, manufacturing processes, performances, and applications and show their advantages in long-term physiological signal monitoring in daily life. In addition, the development directions and challenges of the breathable e-skin are discussed and prospected.
Intraocular pressure (IOP) is the prime indicator for the diagnosis and treatment of glaucoma. IOP has circadian rhythm changes and is dependent on body gestures; therefore, a single measurement in the clinic can be misleading for diagnosis. Herein, few-layer graphene is utilized to develop non-invasive sensors with high transparency, sensitivity, linearity, and biocompatibility for 24 h continuous IOP monitoring. The graphene Wheatstone bridge consisting of two strain gauges and two compensating resistors is designed to improve the sensitivity and accuracy of IOP measurement. Testing results on a silicone eyeball indicate that the output voltage of the sensor is proportional to the IOP fluctuation. Under the various ranges and speeds of IOP fluctuation, the sensor exhibits excellent performance of dynamic cycles and step responses with an average sensitivity of 150 μV/mmHg. With the linear relationship, the average relative error between the calibrated IOP and the standard pressure is maintained at about 5%. More than 100 cycles and interval time measurements illustrate that the sensor possesses significant stability, durability, and reliability. Furthermore, a wireless system is designed for the sensor to realize IOP monitoring using a mobile phone. This sensor, with the average transparency of 85% and its ease of fabrication, as well as its portability for continuous IOP monitoring, brings new promise to the diagnosis and treatment of glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.