The wet bulb globe temperature (WBGT) is the de facto standard to assess environmental contributions to heat stress. A practical problem emerges when the heat stress conditions vary over many locations or during the day. To address this problem, investigators have suggested empirical relationships and thermodynamic models. The purpose of this effort was to examine a thermodynamic model in the laboratory and to predict WBGTs in an aluminum smelter by both the empirical and thermodynamic models. In the laboratory, there was no real difference between the experimental data and the thermodynamic model. In the application to an aluminum smelter, there was a small overall tendency for the predicted values to be greater than the actual values, but there was no practical difference between the models. The empirical model provided a good match with a slight over-prediction by 0.5 degree C with a standard deviation of 3.0 degrees C. For the same data, the thermodynamic model had an average over-prediction of 0.7 degree C with a standard deviation of 2.8 degrees C. Either method of predicting WBGT was effective. The empirical method required less computation and was conceptually simpler.
Threshold limit values for heat stress and strain are based on an upper limit wet bulb globe temperature (WBGT) for ordinary work clothes, with clothing adjustment factors (CAF) for other clothing ensembles. The purpose of this study was to determine the CAF for four clothing ensembles (Cotton Coveralls, Tyvek 1424 Coveralls, NexGen Coveralls, and Tychem QC Coveralls) against a baseline of cotton work clothes and to determine what effect relative humidity may have. A climatic chamber was used to slowly increase the level of heat stress by increasing air temperature at three levels of relative humidity (20%, 50%, and 70%). Study participants wore one of the five ensembles while walking on a treadmill at a moderate metabolic rate of 155 W m-2 (about 300 W). Physiological data and environmental data were collected. When the participant's core temperature reached a steady state, the dry bulb temperature was increased at constant relative humidity. The point at which the core temperature began to increase was defined as the inflection point. The environmental temperature recorded 5 min before the inflection point was used to calculate the critical WBGT for each ensemble. A three-way analysis of variance with ensemble by humidity protocol interactions and a multiple comparison test were used to make comparisons among the mean values. Only the vapor-barrier ensemble (Tychem QC) demonstrated an interaction with humidity level. The following CAFs are proposed: Cotton Coveralls (0 degrees C-WBGT), Tyvek 1424 Coveralls (+1), NexGen Coveralls (+2), and Tychem QC Coveralls (+10).
Although the association with stair climbing was found in other investigations for knee OA, it was also associated with foot OA in this study. In addition, the jolting feature was seen in only one other study for men (knees) and novel for women (hands).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.