In this paper practical ultrasonic C-scan techniques for NDT of laminated composite materials are developed and applied, with an aim to trace specific artificial defects. Two types of materials are examined; an advanced carbon/epoxy system and a typical marine type glass/polyester system. Both were constructed with two manufacturing methods (Hand Lay-Up and Vacuum Infusion). Several artificial defects were embedded into the test plates, varying in shape, magnitude and through thickness position. Test plates were C-scanned using ULTRAPAC II ultrasonic system with ULTRAWIN software and typical examination techniques (layer to layer examination, full width examination, etc.) were used to determine and characterize defects. In addition, appropriate software tuning procedures and examination strategies were applied, which further developed and optimised tthe scanning procedure. These efforts resulted in effective C-scan images, allowing the determination of the position and even the shape of the defects in some cases. Finally, precise determination of specimens' thickness was achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.