Cardiogenic shock during a pheochromocytoma crisis is a life-threatening disorder. This case report illustrates a 49-year-old male with profound cardiogenic shock, extreme hemodynamic instability (systolic blood pressure ranging from 45 up to 290 mmHg in a cyclic pattern), and progressive multiple organ failure in the presence of a unilateral adrenal mass. Emergency adrenalectomy led to rapid hemodynamic stabilization. Histological investigation confirmed the diagnosis of pheochromocytoma. This case indicates that emergency adrenalectomy, although usually not considered first choice, is a valid option in cardiogenic shock and extremely fluctuating hemodynamics due to a pheochromcytoma-induced catecholamine storm.
Microvascular obstruction is a transient phenomenon of “no reflow” after myocardial infarction or radiofrequency ablation, diagnosed using late gadolinium enhancement cardiac MRI. We present a patient with a persistent microvascular obstruction-like lesion following radiofrequency ventricular tachycardia ablation post-myocardial infarction, which was best characterized by a novel dark-blood late gadolinium enhancement technique.
Background
Visually guided laser balloon (VGLB) ablation is a balloon-based treatment for atrial fibrillation (AF) that uses a titratable laser energy source to perform pulmonary vein isolation (PVI), allowing for real-time visualization of target tissue and ablation lesions through an endoscopic camera. Few long-term data on this technique are currently available. This report presents acute efficacy, procedural data, complication rates, and long-term AF-free survival up to 5 years post-ablation.
Methods
In this single-center, retrospective, observational report, 152 patients (72.4% male, mean age 60.6 ± 9.7 years, 62.5% paroxysmal AF, 598 pulmonary veins in total) treated with the first-generation VGLB system between 2014 and 2016 were included for analysis. AF ablation consisted of PVI only.
Results
Acute PVI was achieved in 98.2% of veins, with first-pass isolation in 92.5%. Procedure duration of 129 min [IQR 113–150], fluoroscopy time of 15 min [IQR 11–20], and dose area product of 5016 mGy·cm2 [IQR 3603–8711] were recorded. During a median follow-up of 51 months [IQR 45–57], 74.3% of patients remained free of AF (78.8% for paroxysmal and 65.3% for persistent AF, p = 0.108). Freedom of AF at 1, 2, 3, and 4 years follow-up was 88.2%, 82.2%, 78.9%, and 74.8%, respectively. PV reconnections were identified in only 46.9% of redo procedures. The median number of PV reconnections during redo procedures was 0 [IQR 0–2]. Anti-arrhythmic drug use was significantly reduced after ablation (p < 0.001). The most commonly reported complications were minor vascular complications (4.6%) and transient phrenic nerve paralysis (3.3%).
Conclusions
First-generation VGLB ablation demonstrated high acute isolation rates, reasonable procedure times and low complication rates. Long-term freedom from AF was 78.8% for paroxysmal AF and 65.3% for persistent AF, performing PVI only.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.