Endoscopic submucosal dissection (ESD) has emerged as a novel technique for achieving en bloc resection for superficial neoplasms limited to the mucosa. ESD was originally developed in Japan as a method of endoscopic resection of superficial gastric cancers. In our hospital, ESD has been used concurrently in other parts of the gastrointestinal tract, including the esophagus and colorectum from the beginning of its development. However, ESD in the duodenum is considered more challenging than other parts. From August 2005 to March 2008, a total of 15 superficial duodenal neoplastic lesions in 14 patients were treated with endoscopic resection. Of these, nine underwent ESD. We report our experience with duodenal ESD with a combination of ST hood and hook knife.
BACKGROUND & AIMS: We performed a large, multicenter, randomized controlled trial to determine the efficacy and safety of early colonoscopy on outcomes of patients with acute lower gastrointestinal bleeding (ALGIB). METHODS: We performed an open-label study at 15 hospitals in Japan of 170 patients with ALGIB randomly assigned (1:1) to groups that underwent early colonoscopy (within 24 hours of initial visit to the hospital) or elective colonoscopy (24-96 hours after hospital admission). The primary outcome was identification of stigmata of recent hemorrhage (SRH). Secondary outcomes were rebleeding within 30 days, endoscopic treatment success, need for transfusion, length of stay, thrombotic events within 30 days, death within 30 days, and adverse events. RESULTS: SRH were identified in 17 of 79 patients (21.5%) in the early colonoscopy group vs 17 of 80 patients (21.3%) in the elective
Previously, it has been shown that integrin alpha6beta1 expressed on human granulosa cells regulates luteinization in co-operation with its ligand, laminin. In this study, integrin alpha2 was immunohistochemically demonstrated to be expressed on granulosa and large luteal cells. It was also detected on luteinizing theca interna cells after ovulation. Immunoreactive collagen type IV, which is one of the ligands for integrin alpha2beta1, was detected around granulosa cells in the pre-ovulatory follicles and its expression was rapidly increased during ovulation. By flow cytometry, collagen type IV was detected on the cell surface of luteinizing granulosa cells isolated from pre-ovulatory follicles, confirming the physiological interaction between granulosa cells and collagen type IV. Collagen type IV in follicular fluid was positively related with progesterone concentration. In 4-day cultures of granulosa cells, collagen type IV in the media was significantly increased by human chorionic gonadotrophin (HCG). The progesterone production was significantly attenuated when granulosa cells were cultured on collagen type IV-coated dishes, suggesting that collagen type IV suppresses granulosa cell luteinization. These findings show that collagen type IV, a ligand for integrin alpha2beta1, is rapidly produced around luteinizing granulosa cells during ovulation, probably under the control of luteinizing hormone (LH) and suggest that collagen type IV is a new parameter and/or regulator of granulosa cell luteinization in the periovulatory phases.
OBJECTIVES:The objective of this study was to assess prospectively the diagnostic accuracy of computer-assisted computed tomographic colonography (CTC) in the detection of polypoid (pedunculated or sessile) and nonpolypoid neoplasms and compare the accuracy between gastroenterologists and radiologists.METHODS:This nationwide multicenter prospective controlled trial recruited 1,257 participants with average or high risk of colorectal cancer at 14 Japanese institutions. Participants had CTC and colonoscopy on the same day. CTC images were interpreted independently by trained gastroenterologists and radiologists. The main outcome was the accuracy of CTC in the detection of neoplasms ≥6 mm in diameter, with colonoscopy results as the reference standard. Detection sensitivities of polypoid vs. nonpolypoid lesions were also evaluated.RESULTS:Of the 1,257 participants, 1,177 were included in the final analysis: 42 (3.6%) were at average risk of colorectal cancer, 456 (38.7%) were at elevated risk, and 679 (57.7%) had recent positive immunochemical fecal occult blood tests. The overall per-participant sensitivity, specificity, and positive and negative predictive values for neoplasms ≥6 mm in diameter were 0.90, 0.93, 0.83, and 0.96, respectively, among gastroenterologists and 0.86, 0.90, 0.76, and 0.95 among radiologists (P<0.05 for gastroenterologists vs. radiologists). The sensitivity and specificity for neoplasms ≥10 mm in diameter were 0.93 and 0.99 among gastroenterologists and 0.91 and 0.98 among radiologists (not significant for gastroenterologists vs. radiologists). The CTC interpretation time by radiologists was shorter than that by gastroenterologists (9.97 vs. 15.8 min, P<0.05). Sensitivities for pedunculated and sessile lesions exceeded those for flat elevated lesions ≥10 mm in diameter in both groups (gastroenterologists 0.95, 0.92, and 0.68; radiologists: 0.94, 0.87, and 0.61; P<0.05 for polypoid vs. nonpolypoid), although not significant (P>0.05) for gastroenterologists vs. radiologists.CONCLUSIONS:CTC interpretation by gastroenterologists and radiologists was accurate for detection of polypoid neoplasms, but less so for nonpolypoid neoplasms. Gastroenterologists had a higher accuracy in the detection of neoplasms ≥6 mm than did radiologists, although their interpretation time was longer than that of radiologists.
Purpose To evaluate the diagnostic accuracy and patient acceptance of reduced-laxative computed tomographic (CT) colonography without computer-aided detection (CAD) for the detection of colorectal polypoid and non-polypoid neoplasms in a population with a positive recent fecal immunochemical test (FIT). Materials and Methods Institutional review board approval and written informed consent were obtained. This multicenter prospective trial enrolled patients who had positive FIT results. Reduced-laxative CT colonography and colonoscopy were performed on the same day. Patients received 380 mL polyethylene glycol solution, 20 mL iodinated oral contrast agent, and two doses of 20 mg mosapride the day before CT colonography. The main outcome measures were the accuracy of CT colonography for the detection of neoplasms 6 mm or larger in per-patient and per-lesion analyses and a survey of patient perceptions regarding the preparation and examination. The Clopper-Pearson method was used for assessing the 95% confidence intervals of per-patient and per-lesion accuracy. Survey scores were analyzed by using the Wilcoxon and χ tests. Results Three hundred four patients underwent both CT colonography and colonoscopy. Per-patient sensitivity, specificity, positive predictive value, and negative predictive value of CT colonography for detecting neoplasms 10 mm or larger were 0.91 (40 of 44), 0.99 (255 of 258), 0.93 (40 of 43), and 0.98 (255 of 259), respectively; these values for neoplasms 6 mm or larger were 0.90 (71 of 79), 0.93 (207 of 223), 0.82 (71 of 87), and 0.96 (207 of 215), respectively. Per-lesion sensitivities for detection of polypoid and non-polypoid neoplasms 10 mm or larger were 0.95 (40 of 42) and 0.67 (six of nine), respectively; those for neoplasms 6 mm or larger were 0.90 (104 of 115) and 0.38 (eight of 21), respectively (P < .05 for both). Patient acceptance of preparation and examination with CT colonography was significantly higher than that with colonoscopy, and 62% (176 of 282) of patients would choose CT colonography as the first examination if they have a positive FIT result in the future. Conclusion Reduced-laxative CT colonography without CAD is accurate in the detection of polypoid neoplasms 6 mm or larger but is less accurate in the detection of non-polypoid neoplasms. Reduced-laxative CT colonography has high patient acceptance and is an efficient triage examination for patients with a positive FIT. RSNA, 2016 Online supplemental material is available for this article.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.