This study was carried out to determine 3D-position of selected points within Obafemi Awolowo University. The points were located at Africa Regional Institute for Geospatial Information Science and Technology (AFRIGST), Central Technological and Laboratory Workshops (CTLW), main Bus Stop, Religion ground, New Environmental Design and Management (New EDM), and Spider building. China HuaCe Corporation (CHC) GPS and Promark 3 GPS were used to carry out observation on the selected points. The data gotten were post processed using GNSS solution software for Promark3, Compass software for CHC GPS and the result gotten were compared with the known coordinates of those points. The data was analyzed using Statistical Package for Social Sciences (SPSS) to determine the most accurate instrument between the two. The occupation time for the two instruments on each station was 45 minutes. Analysis of Variance (ANOVA) and Chi square Variance analysis were conducted, the result showed that there is no significant difference between the observations of the two instruments in comparison with the adjusted coordinate. It can be concluded that any of the two instruments can be used for 3D point positioning to obtain accurate result.
This study was carried out to determine 3D-position of selected points within Obafemi Awolowo University. The points were located at Africa Regional Institute for Geospatial Information Science and Technology (AFRIGST), Central Technological and Laboratory Workshops (CTLW), main Bus Stop, Religion ground, New Environmental Design and Management (New EDM), and Spider building. China HuaCe Corporation (CHC) GPS and Promark 3 GPS were used to carry out observation on the selected points. The data gotten were post processed using GNSS solution software for Promark3, Compass software for CHC GPS and the result gotten were compared with the known coordinates of those points. The data was analyzed using Statistical Package for Social Sciences (SPSS) to determine the most accurate instrument between the two. The occupation time for the two instruments on each station was 45 minutes. Analysis of Variance (ANOVA) and Chi square Variance analysis were conducted, the result showed that there is no significant difference between the observations of the two instruments in comparison with the adjusted coordinate. It can be concluded that any of the two instruments can be used for 3D point positioning to obtain accurate result.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.