A suitable method has been developed and validated for the chiral separation and determination of R,S-mephedrone and one of its metabolites, R,S-4-methylephedrine, and R,S-methylenedioxypyrovalerone (R,S-MDPV) in human hair samples by the in-line coupling between SPE and CD-assisted CE with a previous sample pretreatment procedure based on pressurized liquid extraction. Optimum separation was achieved on a fused silica-capillary of 50 μm id and 80 cm total length using 12 mg/mL β-CD in an aqueous solution of 80 mM disodium phosphate at pH 2.5 as the BGE and an applied voltage of 30 kV. The SPE-CE device consists of a short length of a capillary of 2 mm packed with Oasis HLB sorbent, which was inserted near to the inlet end of the CE capillary. Several parameters affecting the in-line preconcentration were evaluated. The LOQs reached for hair samples were 0.05 ng/mg for the enantiomers of mephedrone and its metabolite, and 0.40 ng/mg for the enantiomers of MDPV. The RSDs (%) obtained in intra- and interday studies were less than 10% and the relative recoveries were greater than 80%. The method established in this paper is advantageous for its simplicity, overall analysis time and ability to provide information of both enantiomers of a chiral drug in hair samples.
A simple approach is presented based on the in-line coupling between magnetic particles-based SPE and CE. Silica-coated iron oxide particles functionalized with C18 were successfully synthesized and used as a reverse-phase sorbent for in-line SPE-CE. Magnets were used to locally immobilize these sorbents inside the capillary. Four drugs of abuse were preconcentrated and determined in urine samples using the developed method with a simple pretreatment procedure based on LLE. Several parameters affecting the preconcentration were evaluated. The obtained results show that this strategy enhanced detection sensitivity in the range of 125-700-fold compared with CE without preconcentration. The developed method provides LODs (S/N = 3) for standard samples in the range of 0.5-20 ng/mL with satisfactory analytical precision, in both intraday and day-to-day experiments (RSDs <20%). The LODs (S/N = 3) reached for urine samples were in the range of 20-50 ng/mL. Relative recoveries greater than 75.9% were obtained. The established method has been applied to the analysis of drugs of abuse in urine samples from drug abusers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.