Take-down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.
Biocompatible antimicrobial coatings may enhance the function of many orthopedic implants by combating infection. Hydroxyapatite is a choice mineral for such a coating as it is native to bone and silver would be a possible antimicrobial agent as it is also commonly used in biomedical applications. The aim of the research is to develop a silver-containing calcium phosphate (Ag/Ca-P) coating via electrochemical deposition on titanium substrates as this allows for controlled coating buildup on complex shapes and porous surfaces. Two different deposition approaches are explored: one-step Ag/Ca-P(1) deposition coatings, containing silver ions as microsized silver phosphate particles embedded in the Ca-P matrix; and via a two-step method (Ag/Ca-P(2)) where silver is deposited as metallic silver nanoparticle on the Ca-P coating. The Ag/Ca-P(1) coating displays a bacterial reduction of 76.1 ± 8.3% via Ag-ion leaching. The Ag/Ca-P(2) coating displays a bacterial reduction of 83.7 ± 4.5% via contact killing. Interestingly, by preincubation in phosphate-buffered saline solution, bacterial reduction improves to 97.6 ± 2.7 and 99.7 ± 0.4% for Ag/Ca-P(1) and Ag/Ca-P(2) coatings, respectively, due to leaching of formed AgCl x (x–1)– species. The biocompatibility evaluation indicates that the Ag/Ca-P(1) coating is cytotoxic towards osteoblasts while the Ag/Ca-P(2) coating shows excellent compatibility. The electrochemical deposition of highly bactericidal coatings with excellent biocompatibility will enable us to coat future bone implants even with complex or porous structures.
Calcium phosphate (CaeP) coatings were electrochemically deposited on titanium substrates. By increasing the electrodeposition time (from 1 to 30 min), the coating thickness increases but also the surface morphology of the CaeP coatings is greatly affected going from smooth to plate-like, featuring elongated plates, ribbon-like and finally sharp needle structures. Micro-stretch tests reveal that, regardless of the coating morphology and thickness, the electrodeposited CaeP coatings have strong adhesion with the titanium substrates and their failure mode is cohesive failure. The effects of different morphologies on cellular behavior such as adhesion, viability, proliferation, and osteogenic gene expression were studied. The surface morphology of CaeP coatings has a remarkable effect on cell attachment, proliferation, and viability. A smooth surface results in better adhesion of the cells, whereas the presence of sharp needles and ribbons on rough surfaces restricts cell adhesion and consequently cell proliferation and viability. The improved cell adhesion and viability on the smoother surface can be attributed to the higher contact area between the cell and the coating, while the needle-like morphology inflicts damage to the cells by physically disrupting the cell wall. There is no significant difference in the level of osteoblast gene expression when osteosarcoma cells are cultured on coatings with different morphologies. Our study provides crucial insights into the optimum electrodeposition procedures for CaeP coating formation leading to both good cell-material interaction and sufficient mechanical properties. This can be achieved with relatively thin coatings produced by short electrodeposition times.
The interface between materials and cells plays a critical role in many biomedical applications. Inspired by the hierarchical architecture of collagen, most abundant structure in the extracellular matrix (ECM), a multiscale hierarchical topography is designed to mimic the collagen nano/micro hierarchical topography. It is hypothesized that the ECM topography affects osteogenesis of human mesenchymal stem cells but until now, it cannot be studied without the biochemical and mechanical influences of the ECM. The multiscale hierarchical topography is achieved by innovatively using sequentially aligned topography preparation via a silicone stretch‐oxidation‐release method and imprinting lithography. The anisotropically hierarchical topography influences stem cell morphology, orientation, and osteogenic differentiation. Intriguingly, the design resembling that of assembled collagen, exhibits the highest degree of osteogenesis. The hierarchical topotaxis effects are further exemplified by the enhanced vinculin expression, cell contractility, and more pronounced nuclear translocation of Yes‐associated protein with the collagen‐mimicking topography, indicative for enhanced osteogenesis. The developed multiscale hierarchical system provides insights into the importance of specific biological ECM‐like topography by decoupling the biochemical influence. Various diseases, cancer, osteoarthritis, and fibrosis display impaired ECM structures, and therefore this system may have a great potential for tissue engineering approaches and developing in vitro disease models.
So far, a few chemical solution routes for the fabrication of ferroelectric HfO2 films have been reported. Most of them employ precursors, solvents or additives that are considered difficult to...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.