ObjectivesWhether spinal anaesthesia (SA) reduces intraoperative and postoperative complications compared with general anaesthesia (GA) was investigated.DesignThe meta-analysis was structured based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. Databases (PubMed, MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and Web of Science) were searched, and four randomised controlled trials (RCTs) and two retrospective cohort studies were included. A random-effects model with pooled risk ratios and mean differences with 95% CIs were used. Statistical heterogeneity was evaluated using the I2 statistic. Quality assessment of the studies was performed by assessing the risk of bias according to the Cochrane and GRADE methodology.SettingPublications from January 1990 to November 2018 were included.Participants and interventionsOur study selection captured information from studies focusing on neonates born before the 37th gestational week who were scheduled for an inguinal hernia repair operation under either SA or GA.Primary and secondary outcome measuresThe primary outcome measures were apnoea, postoperative ventilation and method failure rates according to predefined eligibility criteria. The duration of surgery, desaturation events <80%, hospital stay duration and postoperative bradycardia were secondary outcomes.ResultsWe found significantly fewer events for the outcomes ‘any episode of apnoea’ and ‘mechanical ventilation postoperatively’ in the SA group. Bradycardias were significantly less common in the SA group. In total, 7.5% of the SA group were converted to GA. The duration of surgery was significantly shorter in the SA group. No significant differences were found in the outcome measures ‘postoperative oxygen supplementation’, ‘prolonged apnoea’, ‘postoperative oxygen desaturation <80%’ and ‘hospital stay’.ConclusionsWe consider SA a convenient alternative for hernia repair in preterm infants, providing more safety regarding postoperative apnoea. To the best of our knowledge, this is the first meta-analysis to include studies exclusively comparing SA versus GA. More high-quality RCTs are needed.Trial registration numberCRD42016048683
In the concept of a biohybrid lung, endothelial cells seeded on gas exchange membranes form a nonthrombogenic an anti-inflammatory surface to overcome the lacking hemocompatibility of today's oxygenators during extracorporeal membrane oxygenation. To evaluate this concept, the long-term stability and gas exchange performance of endothelialized RGD-conjugated polydimethylsiloxane (RGD-PDMS) membranes was evaluated. Human umbilical vein endothelial cells (ECs) were cultured on RGD-PDMS in a model system under physiological wall shear stress (WSS) of 0.5 Pa for up to 33 days. Gas exchange performance was tested with three biological replicates under elevated WSS of 2.5 Pa using porcine blood adjusted to venous values following ISO 7199 and blood gas analysis. EC morphology was assessed by immunocytochemistry (n = 3). RGD-PDMS promoted endothelialization and stability of endothelialized membranes was shown for at least 33 days and for a maximal WSS of 2.5 Pa. Short-term exposure to porcine blood did not affect EC integrity. The gas transfer tests provided evidence for the oxygenation and decarboxylation of the blood across endothelialized membranes with a decrease of transfer rates over time that needs to be addressed in further studies with larger sample sizes. Our results demonstrate the general suitability of RGD-PDMS for biohybrid lung applications, which might enable long-term support of patients with chronic lung failure in the future.
The potential of the culturable bacterial community from an Alpine coniferous forest site for the degradation of organic polymers and pollutants at low (5 °C) and moderate (20 °C) temperatures was evaluated. The majority of the 68 strains belonged to the phylum Proteobacteria (77%). Other strains were related to Bacteroidetes (12%), Alphaproteobacteria (4%), Actinobacteria (3%), and Firmicutes (3%). The strains were grouped into 42 different OTUs. The highest bacterial diversity was found within the phylum Bacteroidetes. All strains, except one, could grow at temperatures from 5 to 25 °C. The production of enzyme activities involved in the degradation of organic polymers present in plant litter (carboxymethyl cellulose, microgranular cellulose, xylan, polygalacturonic acid) was almost comparable at 5 °C (68%) and 20 °C (63%). Utilizers of lignin compounds (lignosulfonic acid, lignin alkali) as sole carbon source were found to a higher extent at 20 °C (57%) than at 5 °C (24%), but the relative fractions among positively tested strains utilizing these compounds were almost identical at the two temperatures. Similar results were noted for utilizers of organic pollutants (n-hexadecane, diesel oil, phenol, glyphosate) as sole carbon source. More than two-thirds showed constitutively expressed catechol-1,2-dioxygenase activity both at 5 °C (74%) and 20 °C (66%). Complete phenol (2.5 mmol/L) degradation by strain Paraburkholderia aromaticivorans AR20-38 was demonstrated at 0–30 °C, amounts up to 7.5 mmol/L phenol were fully degraded at 10–30 °C. These results are useful to better understand the effect of changing temperatures on microorganisms involved in litter degradation and nutrient turnover in Alpine forest soils.
Purpose: To analyze the changes in target vessel (TV) anatomy after fenestrated endovascular aneurysm repair (fEVAR) during midterm follow-up. Materials and Methods: A retrospective single-center study analyzed 56 patients (mean age 71±7 years; 49 men) who underwent fEVAR using custom-made stent-grafts (22 Zenith and 34 Anaconda) between June 2010 and July 2016. Advanta V12 (V12; 74, 53%) and BeGraft (BeG; 66, 47%) stent-grafts were used to bridge to the 140 TVs. Measurements of the TV deviation at the aortic origin, the vessel shift distal to the bridging stent-graft (BSG), and the outer and inner BSG curve lengths were performed after 3-dimensional reconstruction of the serial computed tomography angiography scans. The results of the measurements for the main devices, the TVs, and the bridging stent-grafts were compared using univariable and multivariable analysis. Results: Of the 140 BSGs examined (74 V12s and 66 BeGs), 393 measurements (38 celiac trunks, 102 superior mesenteric arteries, 121 left renal arteries, and 132 right renal arteries) were analyzed. The outer/inner BSG curve length ratio was larger after implantation of Zenith devices compared with Anaconda (p<0.001). The vessel shift distal to the BSG was significantly associated with the interaction of the TV and type of BSG only in the univariable analysis (p=0.001). There were no significant changes of the TV deviation at the aortic origin. Only the outer BSG curve length was significantly associated with TV complications (p=0.033). Median follow-up was 24 months (range 2–61). The BSG curve length ratio showed a significant increase over time (p<0.001) but did not differ between the BeG and V12 (p=0.381). Conclusion: No difference was found between the V12 and the BeG stent-grafts regarding anatomical TV changes during midterm follow-up after fEVAR. Both stent-grafts adapt to the TV anatomy over time, and moderate anatomical changes seem to be tolerated without increasing the risk for TV complications. The type of main device also influences the TV anatomy.
Multiple lower limits of quantification (MLOQs) result if various laboratories are involved in the analysis of concentration data and some observations are too low to be quantified. For normally distributed data under MLOQs there exists only the multiple regression method of Helsel to estimate the mean and variance. We propose a simple imputation method and two new maximum likelihood estimation methods: the multiple truncated sample method and the multiple censored sample method. A simulation study is conducted to compare the performances of the newly introduced methods to Helsel's via the criteria root mean squared error (RMSE) and bias of the parameter estimates. Two and four lower limits of quantification (LLOQs), various amounts of unquantifiable observations and two sample sizes are studied. Furthermore, the robustness is investigated under model misspecification. The methods perform with decreasing accuracy for increasing rates of unquantified observations. Increasing sample sizes lead to smaller bias. There is almost no change in the performance between two and four LLOQs. The magnitude of the variance impairs the performance of all methods. For a smaller variance, the multiple censored sample method leads to superior estimates regarding the RMSE and bias, whereas Helsel's method is superior regarding the bias for a larger variance. Under model misspecification, Helsel's method was inferior to the other methods. Estimating the mean, the multiple censored sample method performed better, whereas the multiple truncated sample method performs best in estimating the variance. Summarizing, for a large sample size and normally distributed data we recommend to use Helsel's method. Otherwise, the multiple censored sample method should be used to obtain estimates of the mean and variance of data including MLOQs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.