Bacterial YidC, an evolutionally conserved membrane protein, functions as a membrane protein chaperone in cooperation with the Sec translocon and as an independent insertase for membrane proteins. In Gram-negative bacteria, the transmembrane and periplasmic regions of YidC interact with the Sec proteins, forming a multi-protein complex for Sec-dependent membrane protein integration. Here, we report the crystal structure of full-length Escherichia coli YidC. The structure reveals that a hydrophilic groove, formed by five transmembrane helices, is a conserved structural feature of YidC, as compared to the previous YidC structure from Bacillus halodurans, which lacks a periplasmic domain. Structural mapping of the substrate- or Sec protein-contact sites suggested the importance of the groove for the YidC functions as a chaperone and an insertase, and provided structural insight into the multi-protein complex.
The aim of this study was to translate the Cumulated Ambulation Score (CAS) from English into Japanese in cooperation with different types of healthcare providers and to investigate its inter-rater reliability and internal consistency. Methods: Two physical therapists at each of three general hospitals in Japan measured the mobility of 50 consecutive post-operative hip fracture patients on two occasions between 2 and 6 days after surgery using the Japanese version of the CAS (CAS-JP). We analyzed the inter-rater reliability and agreement using both the linear weighted kappa and the interclass correlation coefficient; we also analyzed the internal consistency using Cronbach's alpha coefficient. Results: The mean age of patients was 81 (SD: 11.6) years and 82% were women. Approximately half of the patients had severe cognitive impairment. Kappa was ≥ 0.93 for the three mobility activities and for the total CAS-JP score, the percentage agreement was ≥ 0.98, the ICC was ≥ 0.95, and Cronbach's alpha coefficient was 0.85. Conclusions: We found that the CAS-JP possessed good inter-rater reliability, agreement, and internal consistency. The CAS-JP is a reliable and easy-to-use evaluation tool suitable for daily clinical practice across different healthcare providers to monitor mobility in older hip fracture patients in Japan. We suggest that CAS-JP be evaluated in future studies for use in younger patients and in other patient groups with mobility problems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.