New variants of porcine epidemic diarrhoea virus (PEDV) causing a highly contagious intestinal disease, porcine epidemic diarrhoea virus (PED), have resulted in high mortality in suckling pigs across several countries since 2013. After 2015, the prevalence of the genogroup 2b (G2b) PEDVs decreased in a cyclical pattern with endemic seasonal outbreaks occasionally seen. To better understand the genetic diversity of PEDVs recently circulating in Taiwan, full‐length spike (S) genes of 31 PEDV strains from 28 pig farms collected during 2016–2018 were sequenced. While the majority of S gene sequences (from 27/28 farms) were closely related to the previous G2b PEDV strains, increased genetic diversities leading to several nonsynonymous mutations scattering in the neutralizing epitopes of the S gene were detected in PEDVs recently circulating in Taiwan. Furthermore, novel recombinant variants, the PEDV TW/Yunlin550/2018 strains exhibiting recombinant events between a previously isolated Taiwan PEDV G2b strain and a wild‐type PEDV G1a strain, were identified and further classified into a new genogroup, G1c. These results provide updated information about the genetic diversity of currently circulating PEDVs in the field and could help to develop more suitable strategies for controlling this disease.
Toward the achievement of noninvasive and continuous monitoring of blood glucose level, we developed a new measurement method based on the continuous-wave photoacoustic (CW-PA) technique and performed the first validation in vitro with calibrated aqueous glucose solutions. The PA technique has been studied in the past but exclusively based on the pulse setup since the CW one exhibits dependence on the cavity dimensions, which is not compatible with the final application requirements. This paper describes a new strategy relying on the monitoring of the resonant-frequency relative shift induced by the change of glucose concentrations rather than amplitude signal levels at a fixed frequency. From in vitro results, we demonstrate a stable and reproducible response to glucose at various cavity dimensions and optical wavelengths, with a slope of 0.19 ±0.01%/g/dL. From theoretical considerations, this method is consistent with a relative acoustic velocity measurement, which also explains the aforementioned stability. The proposed method then resolves most of the issues usually associated with the CW-PA technique and makes it a potential alternative for the noninvasive and continuous monitoring of glycemia levels. However, experimental determination of sensor responses to albumin and temperature as two potential interferents shows similar levels, which points to the selectivity to glucose as a major issue we should deal with in future development.
The effects of acid generation efficiency and other properties on the resolution, line width roughness (LWR), and sensitivity (RLS) tradeoff for extreme ultraviolet (EUV) photoresists were evaluated under electron beam (EB) exposure. The acid generators (AGs) introducing a trifluoromethyl group as an electron-withdrawing group on the sulfur atom had a much higher reduction potential than current AGs. We determined acid generation efficiency by the 13 C-NMR method and standard titration. The dissolution inhibitory effect on the alkaline developer and the thermal property of the resist film using each AG were also evaluated. The RLS performance of resists containing AGs with a higher acid generation efficiency than conventional AGs was characterized using the relative Z -factor under EB exposure. #
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.