The mean diameters of the lymphatic vessels and the veins were 0.242 mm (range, 0.20 to 0.35 mm) and 0.471 mm (range, 0.30 to 0.75 mm), respectively. Intraoperative patency was 100 percent (six of six) in both groups (p = 1.000). Postoperative patency was significantly higher in the lymphaticovenular anastomosis group compared with the lymphaticovenous implantation group [100 percent (six of six) versus 33.3 percent (two of six); p = 0.014] CONCLUSION:: Postoperative patency of the lymphaticovenular anastomosis group was higher than that of the lymphaticovenous implantation group, although intraoperative patency rates of the lymphaticovenular anastomosis and lymphaticovenous implantation groups were comparable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.