BackgroundThrombocytopenia represents an obstacle for invasive procedures in chronic liver disease (CLD) patients. We aimed to estimate the appropriate dose and evaluate the efficacy and safety of lusutrombopag for the treatment of thrombocytopenia before percutaneous liver radiofrequency ablation (RFA) for primary hepatic cancer in patients with CLD.MethodsIn this multicenter, randomized, double-blind, placebo-controlled study conducted in Japan, 61 CLD patients with platelet count < 50 × 103/µL at screening were randomized to placebo or lusutrombopag 2, 3, or 4 mg once daily for 7 days, followed by a 28-day post-treatment assessment period. The primary efficacy endpoint was the proportion of patients who did not require platelet transfusion before RFA. The pre-specified key secondary efficacy endpoint was the proportion of responders. Adverse events (AEs) and thrombosis-related AEs were evaluated.ResultsThe proportion of patients who did not require platelet transfusion before RFA and that of responders were significantly higher (p < 0.01) in the 2-mg (80.0, 66.7%), 3-mg (81.3, 68.8%), and 4-mg groups (93.3, 80.0%) compared with the placebo group (20.0, 6.7%) and showed a dose-dependent effect. The incidence of AEs was 97.8 and 100% in the lusutrombopag (all groups) and placebo groups, respectively; no dose-related increase was observed. Four patients experienced thrombosis-related events (one each in the placebo and 2-mg groups, and two in the 4-mg group). A total of 16 (18%) adverse drug reactions occurred in the safety analysis set.ConclusionsLusutrombopag 3 mg once daily for 7 days was effective without raising concerns about excessive increases in platelet count.Clinical trial registrationThe study is registered at JapicCTI-121944.Electronic supplementary materialThe online version of this article (10.1007/s00535-018-1499-2) contains supplementary material, which is available to authorized users.
The aims of this study were to evaluate the utility of shear wave elastography (SWE) using acoustic radiation force impulse (ARFI) for diagnosing chronic autoimmune thyroiditis (CAT) and to verify the effect of fibrotic thyroid tissue on shear wave velocity (SWV). The subjects were 229 patients with 253 normal thyroid lobes (controls) and 150 CAT lobes. The SWV for CAT (2.47 ± 0.57 m/s) was significantly higher than that for controls (1.59 ± 0.41 m/s) (P < 0.001). The area under the receiver operating characteristics (ROC) curve for CAT was 0.899, and the SWV cut-off value was 1.96 m/s. The sensitivity, specificity, and diagnostic accuracy were 87.4%, 78.7%, and 85.1%, respectively. Levels of anti-thyroperoxidase antibodies and thyroid isthmus thickness were correlated with tissue stiffness in CAT. However, there was no correlation between levels of anti-thyroglobulin antibodies and tissue stiffness. Quantitative SWE is useful for diagnosing CAT, and it is possible that SWE can be used to evaluate the degree of fibrosis in patients with CAT.
A new Encryption-then-Compression (ETC) system for the JPEG 2000 standard is proposed in this paper. An ETC system is known as a system that makes image communication secure and efficient by using perceptual encryption and image compression. The proposed system uses the sign-scrambling and block-shuffling of discrete wavelet transform (DWT) coefficients as perceptual encryption. Unlike conventional ETC systems, the proposed system is compatible with the JPEG 2000 standard because the perceptually encrypted coefficients can be efficiently compressed by the JPEG 2000. The experimental results demonstrated that the proposed system achieved both acceptable compression performance and enough key-space for secure image communication while remaining compatible with the JPEG 2000 standard.
This multicenter, double-blind, phase 2a part of a phase 2/3 study assessed the efficacy and safety of ensitrelvir, a novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) 3C-like protease inhibitor, in Japanese patients with mild-to-moderate coronavirus disease 2019 (COVID-19) or asymptomatic SARS-CoV-2 infection. Sixty-nine patients were randomized (1:1:1) to orally receive 5-day ensitrelvir fumaric acid (375 mg on day 1 followed by 125 mg daily, or 750 mg on day 1 followed by 250 mg daily) or placebo and followed up until day 28.
BackgroundUltrasonography is a non-invasive technique that is commonly used by endocrinologists and endocrine surgeons to examine the thyroid region and could be useful for the assessment of vocal cord movement by these specialists. However, previous studies reported a low rate of successful visualization of vocal cord movement by ultrasonography. To address this issue, we devised a novel ultrasonographic procedure for assessing vocal cord movement indirectly by observing the arytenoid movement from a lateral view.MethodsSubjects were 188 individuals, including 23 patients with vocal cord paralysis and 13 with vocal cord paresis. We performed ultrasonographic assessment of vocal cord movement using two different procedures: the conventional middle transverse procedure and the novel lateral vertical procedure.ResultsThe rate of visualization of vocal cords with the middle transverse procedure was 70.2% and that of the arytenoid cartilage with the lateral vertical procedure was 98.4%. The lateral vertical procedure enabled visualization of all patients with vocal cord paresis/paralysis and detected all 23 patients with vocal paralysis; only one of 13 patients with vocal cord paresis was positively identified. The conventional procedure enabled visualization of 21 of 36 patients with vocal cord paresis/paralysis with high accuracy. There was no false-positive case in either procedure.ConclusionThe proposed lateral vertical procedure improved the rate of visualization of vocal cord movement by ultrasonography, suggesting that it is a useful technique to screen for vocal cord paralysis by ultrasonography.Electronic supplementary materialThe online version of this article (doi:10.1007/s00268-017-4151-z) contains supplementary material, which is available to authorized users.
Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.