This study, to our knowledge, is the first to explore the effects of nivolumab against ovarian cancer. The encouraging safety and clinical efficacy of nivolumab in patients with platinum-resistant ovarian cancer indicate the merit of additional large-scale investigations (UMIN Clinical Trials Registry UMIN000005714).
Sentinel lymph node (SLN) biopsy using indocyanine green (ICG) fluorescence is safe and has a high detection rate for SLNs. However, the results of this novel technique are heterogeneous. The objective of this meta-analysis was to evaluate the diagnostic performance of the ICG fluorescence method compared with the standard radioisotope (RI) method. All eligible studies were identified from 2005 through 2015. A proportion meta-analysis was performed using a fixed effects and/or random effects model based on the study heterogeneity. A total of 12 studies met the inclusion criteria and included 1736 women. There was no significant difference between ICG fluorescence and RI for SLN detection using either the fixed effects model [odds ratio (OR) 1.29, 95% confidence interval (CI) 0.87-1.90] or the random effects model (OR 1.32, 95% CI 0.54-3.18). There were seven studies reporting the detection rate for tumor-positive SLN. The ICG fluorescence method was significantly better than the RI method in the fixed effects model (OR 1.87, 95% CI 1.00-3.49) for staging axilla. However, there was no difference in the random effects model (OR 1.90, 95% CI 0.74-4.86). There was study outcome heterogeneity for the detection of SLN but not for tumor-positive SLN. There was no publication bias observed in the studies included. The ICG fluorescence method has valid diagnostic performance for SLN detection and shows a trend toward better axilla staging compared with the RI method. ICG fluorescence is a useful alternative to RI for SLN biopsy.
High rate of SLN detection was achieved using the ICG fluorescence method. The first SLN identified by fluorescence imaging provides an exact indication of the axillary status. Therefore, the ICG fluorescence method provides precise information required to avoid unnecessary ALND.
Novel Mg2+ fluorescent molecular probes (KMG-20-AM and KMG-27-AM; where AM is an acetoxymethyl group) based on a coumarin possessing a charged beta-diketone structure were designed and synthesized. These fluorescent probes produced a red shift from 425 to 445 nm in the absorption spectra after formation of a complex with Mg2+. The fluorescence spectra of these probes also showed a red shift from 485 to 495 nm and an increasing fluorescence intensity after formation of a complex with Mg2+. The optimum experimental conditions were excitation wavelength of 445 nm and a monitored wavelength of 500 nm, where these probes functioned as an indicator showing an image of increasing fluorescence in the presence of Mg2+. These probes showed a "seesaw-type" fluorescent spectral change with the isosbestic point at 480 nm due to the light excitation at 445 nm, which indicates that ratiometry can be used for the measurement. The molecular probes formed a 1:1 complex with Mg2+ and the dissociation constant (Kd) was 10.0 mM for KMG-20. The association constants of the probes with Mg2- were approximately 3 times higher than that with Ca2+, which showed that the selectivity of Mg2+ versus Ca2+ for these probes was over 200 times higher than that for commercially available Mg2+ fluorescent molecular probes such as mag-fura-2, Magnesium Green. As an application of these probes, intracellular fluorescent imaging of Mg2+ was demonstrated using a fluorescent microscope. After the addition of KMG-20-AM and KMG-27-AM into PC12 cells, a strong fluorescence was observed in the cytoplasm and a weak fluorescence in the nuclei region. After treatment with a high-K+ medium, the fluorescence intensity increased due to increasing intracellular Mg2+. The real image of Mg2+ release from the magnesium store was successfully observed with these Mg2+ fluorescent probes.
Purpose. This study compared the clinical utility of indocyanine green (ICG) fluorescence and radioisotope (RI) for sentinel lymph node (SLN) detection in breast cancer. Methods. Women with node-negative breast cancer underwent SLN biopsy using ICG fluorescence and RI. The primary end point was the sensitivity of ICG fluorescence compared with RI in the patients with tumor-positive SLNs. Secondary end points included detection rates for SLN, the additive effect of ICG fluorescence to RI, signature of positive SLNs according to tier, and adverse events related to ICG administration. Results. A total of 847 women with clinical node-negative breast cancer underwent SLN biopsy, and 821 patients were included in the per-protocol analysis. SLN mapping was performed using ICG fluorescence and RI. The overall detection of SLNs using ICG fluorescence was identical to RI (97.2 vs. 97.0 %, P = 0.88), and the combination of both methods achieved a significant improvement compared with RI alone (99.8 vs. 97.0 %, P \ 0.001). The detection rate for tumor-positive SLN was 93.3 % for ICG fluorescence and 90.0 % for RI, and the sensitivity of the ICG fluorescence method was 95.7 % (95 % CI 91.3-98.3, P = 0.11). The additional use of ICG significantly improved positive SLN detection for RI (97.2 vs. 90.0 %, P \ 0.001). There were no serious adverse events related to hypersensitivity to ICG. Conclusions. The ICG fluorescence method may be an acceptable alternative to SLN detection using RI in breast cancer.Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, and the dual tracer method using radioisotope (RI) and blue dye achieves the highest detection rates for SLN. 1-3 However, the applicability of RI is limited to large-volume centers with available RI facilities and nuclear medicine. The dye method is cost-effective, but it has drawbacks, such as a low detection rate and the need for significant physician skill and experience. 4 A novel method using indocyanine green (ICG) fluorescence was developed in
BackgroundTo date, no therapeutic option has been established for sudden deafness refractory to systemic corticosteroids. This study aimed to examine the efficacy and safety of topical insulin-like growth factor-1 (IGF-1) therapy in comparison to intratympanic corticosteroid therapy.MethodsWe randomly assigned patients with sudden deafness refractory to systemic corticosteroids to receive either gelatin hydrogels impregnated with IGF-1 in the middle ear (62 patients) or four intratympanic injections with dexamethasone (Dex; 58 patients). The primary outcome was the proportion of patients showing hearing improvement (10 decibels or greater in pure-tone average hearing thresholds) 8 weeks after treatment. The secondary outcomes included the change in pure-tone average hearing thresholds over time and the incidence of adverse events.ResultsIn the IGF-1 group, 66.7% (95% confidence interval [CI], 52.9–78.6%) of the patients showed hearing improvement compared to 53.6% (95% CI, 39.7–67.0%) of the patients in the Dex group (P = 0.109). The difference in changes in pure-tone average hearing thresholds over time between the two treatments was statistically significant (P = 0.003). No serious adverse events were observed in either treatment group. Tympanic membrane perforation did not persist in any patient in the IGF-1 group, but did persist in 15.5% (95% CI, 7.3–27.4%) of the patients in the Dex group (P = 0.001).ConclusionsThe positive effect of topical IGF-1 application on hearing levels and its favorable safety profile suggest utility for topical IGF-1 therapy in patients with sudden deafness.Trial registrationUMIN Clinical Trials Registry Number UMIN000004366, October 30th, 2010.
A novel ammonium ionophore, which exhibits superior NH4+ selectivity compared with that of the natural antibiotic nonactin, was successfully designed and synthesized based on a 19-membered crown compound (TD19C6) having three decalino subunits in the macrocyclic system. This bulky decalino subunit is effective for (1) increasing the structural rigidity of the cyclic compound, (2) introducing the "block-wall effect", which prevents forming a complex with a large ion, and (3) increasing the lipophilicity of the ionophore molecule. In the ammonium ionophore design, the first factor contributes to increasing the NH4+ selectivity relative to smaller ions such as Li+, Na+, or even the closest size, K+, and the second factor increases the NH4+ selectivity over larger ions such as Rb+ and Cs+. The X-ray structural analysis proved that TD19C6 forms a size-fit complexwith NH4+ in its crown ring cavity. As an application of this ionophore, an ion sensor (ion-selective electrode) was prepared, which exhibited NH4+ to K+ and Na+ selectivity of 10 and 3,000 times, respectively. This electrode showed a better performance compared to the electrode based on nonactin, which is the only ammonium ionophore presently used in practical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.