Masquelet technique, which is the use of a temporary cement spacer followed by staged bone grafting, is a recent treatment strategy to manage a posttraumatic bone defect. This paper describes a series of 9 patients treated with this technique of staged bone grafting following placement of an antibiotic spacer to successfully manage osseous long bone defects. The injured limbs were stabilized and aligned at the time of initial spacer placement. In our series, osseous consolidation was successfully achieved in all cases. This technique gives promising result in the management of posttraumatic bone defects.
Three-dimensional (3-D) printing or additive manufacturing, an advanced technology that 3-D physical models are created, has been wildly applied in medical industries, including cardiothoracic surgery, cranio-maxillo-facial surgery and orthopaedic surgery. The physical models made by 3-D printing technology give surgeons a realistic impression of complex structures, allowing surgical planning and simulation before operations. In orthopaedic surgery, this technique is mainly applied in surgical planning especially revision and reconstructive surgeries, making patient-specific instruments or implants, and bone tissue engineering. This article reviews this technology and its application in orthopaedic surgery.
The aim of this study was to determine the results of operative treatment of distal radial fractures with a 2.4-mm locking plate system in a single tertiary teaching hospital. Seventy-five patients were recruited into the study between May 2004 and November 2006. There were 41 males and 34 females, with a mean age of 51. Seventy-five percent of patients had AO type C fractures. All patients were allowed free active mobilisation of the wrist joint immediately after surgery. They were followed up at two weeks, three months, six months, one year and two years. Assessments of pain, motion, grip strength, and standard radiographs were performed. The Gartland and Werley functional scores, the modified Green and O'Brien score, and the disabilities of the arm, shoulder and hand (DASH) scores were recorded. The radiographic results at the final follow-up showed a mean of 18° of radial inclination, 5° of volar tilt, 1.3-mm radial shortening, and no articular incongruity. Twenty-nine percent of patients showed grade 1 osteoarthritic changes and 6% had grade 2 changes in their final follow-up radiographs. An excellent or good result was obtained in 98% and 96% of patients according to the Gartland and Werley, and modified Green and O'Brien scores, respectively. The mean DASH score was 11.6, indicating a high level of patient satisfaction. Internal fixation of distal radial fractures with a 2.4-mm locking plate system provided a stable fixation with good clinical outcomes and patient satisfaction.
Background It is unclear whether regional anesthesia with infraclavicular nerve block or general anesthesia provides better postoperative analgesia after distal radial fracture fixation, especially when combined with regular postoperative analgesic medications. The aim of this study was to compare the postoperative analgesic effects of regional versus general anesthesia. Methods In this prospective, observer blinded, randomized controlled trial, 52 patients undergoing distal radial fracture fixation received either general anesthesia (n = 26) or regional anesthesia (infraclavicular nerve block, n = 26). Numerical rating scale pain scores, analgesic consumption, patient satisfaction, adverse effects, upper limb functional scores (Patient-Rated Wrist Evaluation, QuickDASH), health related quality of life (SF12v2), and psychological status were evaluated after surgery. Result Regional anesthesia was associated with significantly lower pain scores both at rest and with movement on arrival to the post-anesthetic care unit; and at 1, 2, 24 and 48 h after surgery (p ≤ 0.001 at rest and with movement). Morphine consumption in the post-anesthetic care unit was significantly lower in the regional anesthesia group (p<0.001). There were no differences in oral analgesic consumption. Regional anesthesia was associated with lower incidences of nausea (p = 0.004), and vomiting (p = 0.050). Patient satisfaction was higher in the regional anesthesia group (p = 0.003). There were no long-term differences in pain scores and other patient outcomes. Conclusion Regional anesthesia with ultrasound guided infraclavicular nerve block was associated with better acute pain relief after distal radial fracture fixation, and may be preferred over general anesthesia. Trial registration Before subject enrollment, the study was registered at ClinicalTrials.gov (NCT03048214) on 9th February 2017.
In osteoporotic hip fractures, fracture collapse is deliberately allowed by commonly used implants to improve dynamic contact and healing. The muscle lever arm is, however, compromised by shortening. We evaluated a cohort of 361 patients with AO/OTA 31.A1 or 31.A2 intertrochanteric fracture treated by the dynamic hip screw (DHS) who had a minimal follow-up of 3 months and an average follow-up of 14.6 months and long term survival data. The amount of fracture collapse and shortening due to sliding of the DHS was determined at the latest follow-up and graded as minimal (<1 cm), moderate (1-2 cm), or severe (>2 cm). With increased severity of collapse, more patients were unable to maintain their premorbid walking function (minimal collapse = 34.2%, moderate = 33.3%, severe = 62.8%, and p = 0.028). Based on ordinal regression of risk factors, increased fracture collapse was significantly and independently related to increasing age (p = 0.037), female sex (p = 0.024), A2 fracture class (p = 0.010), increased operative duration (p = 0.011), poor reduction quality (p = 0.000), and suboptimal tip-apex distance of >25 mm (p = 0.050). Patients who had better outcome in terms of walking function were independently predicted by younger age (p = 0.036), higher MMSE marks (p = 0.000), higher MBI marks (p = 0.010), better premorbid walking status (p = 0.000), less fracture collapse (p = 0.011), and optimal lag screw position in centre-centre or centre-inferior position (p = 0.020). According to Kaplan-Meier analysis, fracture collapse had no association with mortality from 2.4 to 7.6 years after surgery. In conclusion, increased fracture collapse after fixation of geriatric intertrochanteric fractures adversely affected walking but not survival.
Radiography alone is not adequate for surgical planning for ankle fractures. More accurate imaging tools such as CT are needed to enable a more accurate diagnosis and surgical planning.
MIPO for fixation of proximal humeral fractures using a locking plate is safe and effective in enabling an early return of shoulder function.
Objectives:This study aims to identify if wintertime surgery increases the mortality of the patients after hip fracture operations.Design:Retrospective observational cohort study.Setting:The data for this citywide retrospective observational cohort study came from Clinical Data Analysis Reporting System.Patient:This study included 35 409 patients with hip fracture operations from July 2005 to December 2013.Main Outcome Measures:Cox regression hazard model was used to estimate the independent effect of operation being performed in winter on the hazard of mortality. The hazard model included covariates found to be independent predictors of mortality: age, sex, surgical delay, and Charlson Comorbidity Index (CCI).Results:There was a seasonal variation with more hip fracture operations happening in the winter months. The 1-month, 6-month, 1-year, and 5-year mortality were 3%, 11%, 17%, and 47%, respectively. Operation performed in winter was associated with a higher hazard of mortality (hazard ratio [HR] 1.040; 95% confidence interval: 1.010-1.072; P = .009). The HR was greater with male sex (HR 1.786; P = .000), advanced age (≥85 years old: HR 2.819; P = .000), the longer surgical delay (HR 1.018; P = .000), and higher CCI (severe CCI group: HR 2.963; P = .000).Conclusion:Wintertime hip fracture surgery was associated with an increased hazard of mortality after adjusting for other known risk factors affecting mortality post hip fracture operations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.