Abstract. This study shows the improvement of muscle activity and muscle strength imbalance in the lower extremities through independent exercise loads in vibration platform. Twenty females of age 20 participated in this study. The subjects were divided into WBV group, with more than 10% of muscle strength imbalance between left and right the lower extremities, and control group, with less than 10% of muscle strength imbalance between left and right the lower extremities. As the prior experiment showed, different exercise postures provide different muscular activities. As a result, the highest muscular activity was found to be in the low squat posture. Therefore, the LS posture was selected for the exercise in this experiment. Vibration intensities were applied to dominant muscle and non-dominant muscle, and the vibration frequency was fixed at 25Hz for the WBV group. The control group was asked to perform the same exercise as the WBV group, without stimulated vibration. This exercise was conducted for a total of 4 weeks. As a result, the WBV group which showed an average deviation of 16% before the experiment, tended to decrease approximately to 5%. In this study, vibration exercise using load deviation is shown to be effective in improving the muscle strength imbalance.
This study investigated that the spinal MFs can create compressive follower loads (CFLs) in the lumbar spine in a dynamic state. Three-dimensional optimization and finite element (FE) models of the spinal system were developed and validated using reported experimental data. An optimization analysis was performed to determine the MFs that create CFLs in the lumbar spine in various sagittal postures from 10° extension to 40° flexion. Optimization solutions for the MFs, CFLs, and follower load path (FLP) location were feasible for all studied postures. The FE predictions demonstrated that MFs which created CFLs along the base spinal curve connecting the geometrical centers or along a curve in its vicinity (within anterior or posterior shift by 2 mm) produced stable deformation of the lumbar spine in the neutral standing and flexed postures, whereas the MFs which created the smallest CFLs resulted in unstable deformation. For extended postures, however, finding CFLs creating MFs that produce stable deformation of the extended spine was not possible. The results of this study support the hypothesis that the spinal muscles may stabilize the spine via the CFL mechanism.
The effect of stent design parameters such as porosity, pore density, number of strands, and strut angle to the artery were studied in vitro using particle image velocimetry (PIV). Five mesh stents were implanted into a sidewall aneurysm model. The flow features in a sidewall aneurysm silicone phantom model were investigated at a Reynolds number of 300. It was found that the lowest porosity stent had the best value for velocity and vorticity reduction in an aneurysm pocket. The stent with higher pore density had a tendency to decrease the mean and maximum velocities, but it was not superior to the effects of porosity. In addition, investigation of the evaluation system confirmed that higher stent strut angles to the parent artery had a tendency to lower mean velocity, as shown by PIV and CFD. However, this effect was relatively smaller compared to porosity and pore density. Our evaluation system suggested the best combinations of parameters for the development of an ideal stent would be lower porosity, higher pore density, and higher strut angle. The results obtained in this study indicated that our evaluation system could be useful for various purposes related to evaluation of endovascular interventional devices.
Abstract. OBJECTIVE:In this paper, we investigated the parameters with effective traceability to assess the mechanical properties of interventional devices. METHODS: In our evaluation system, a box-shaped poly (vinyl alcohol) hydrogel (PVA-H) and silicone were prepared with realistic geometry, and the measurement and evaluation of traceability were carried out on devices using load hand force. The phantom models had a total of five curve pathways to reach the aneurysm sac. RESULTS: Traceability depends on the performance of the interventional devices in order to pass through the curved part of the model simulation track. The traceability of the guide wire was found to be much better than that of the balloon and stent loading catheter, as it reached the aneurysm sac in both phantom models. CONCLUSIONS: Observation using the video record is another advantage of our system, because the high transparency of the materials with silicone and PVA-H can allow visualization of the inside of an artery.
This research was performed to assess the effects of angled whole body vibration on muscle activity of the lower limbs, by examining adults in their twenties during squat exercises, taking into account two variables of exercise intensity (vibration frequency and gradient). Twenty healthy males in their twenties with previous experience of more than 6 month's weight training and no past medical history were included in this study. The experiment was performed by participating in squat exercises which consisted of 3 sets (1 set = 5 seconds x 3 repetitions of exercise), and the muscle activities of the Rectus Femoris, Vastus Lateralis, Vastus Medialis were measured with variation in the gradients of 0°, 10°, and 20°, and vibration frequencies of 20, 30, and 40 Hz. At 30 and 40 Hz, the vastus lateralis showed the highest change in muscle activity, while activity of the vastus medialis also increased significantly. Analysis of muscle activity according to the gradient showed a significant increase of the vastus lateralis at 20°, while the highest muscle activity at 20° was observed for the vastus medialis. In comparison of the change in lower limb muscle activity according to simultaneous stimulation, at a gradient of 10°, high activity was shown in muscle, while at 20°, high muscle activities were produced at 40 Hz in the vastus lateralis, 40 Hz in the rectus femoris, and both 30 and 40 Hz in the vastus medialis
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.